added 2020/11/19 9:5 p.m.75 views

CVE-2020-7544

CVE-2020-7544 affects Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD). A CWE-269 improper privilege management vulnerability could enable privilege escalation on a workstation when interacting with a driver installed by the runtime. The vulnerability is reported for Eco...

7.8CVSS7.7AI score0.00313EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/11/19 9:4 p.m.77 views

CVE-2020-7559

Schneider Electric EcoStruxure Control Expert PLC Simulator Modbus processing vulnerability (CVE-2020-7559) is a stack-based buffer overflow in the Modbus message handling path. In the TALOS report, a large Modbus request can be written into a stack buffer of 0x8000 bytes via memcpy without lengt...

7.5CVSS7.4AI score0.01905EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:4 p.m.57 views

CVE-2020-7559

A CWE-120: Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially...

7.5AI score0.01905EPSS
SaveExploits1References2
Cvelist
Cvelist
added 2020/11/19 9:4 p.m.43 views

CVE-2020-7538

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request...

7.5AI score0.01288EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/19 9:4 p.m.66 views

CVE-2020-7538

CVE-2020-7538 affects the PLC Simulator for EcoStruxure Control Expert (Unity Pro) across all versions. The flaw is CWE-754: Improper Check for Unusual or Exceptional Conditions, which could crash the PLC simulator when it receives a specially crafted Modbus request. Affected: PLC Simulator for E...

7.5CVSS7.5AI score0.01288EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.51 views

CVE-2020-28213

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when sending specially crafted requests over Modbus...

8.9AI score0.01178EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/19 9:3 p.m.61 views

CVE-2020-28213

Across multiple sources, CVE-2020-28213 affects Schneider Electric EcoStruxure Control Expert (Unity Pro) PLC Simulator, with the flaw lying in downloading code without integrity checking via Modbus. The vulnerability allows unauthorized command execution on all versions, as reported in CVE recor...

8.8CVSS8.8AI score0.01178EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/11/19 9:3 p.m.69 views

CVE-2020-28212

CVE-2020-28212 describes an authentication- bypass risk in EcoStruxure Control Expert PLC Simulator (Unity Pro) via brute-forcing Modbus sessions. Root cause: CWE-307 improper restriction of excessive authentication attempts, enabling a remote attacker to gain unauthorized command execution with ...

9.8CVSS9.5AI score0.02757EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.34 views

CVE-2020-28212

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when a brute force attack is done over Modbus...

9.6AI score0.02757EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/19 9:3 p.m.66 views

CVE-2020-28211

CVE-2020-28211 affects Schneider Electric EcoStruxure Control Expert (PLC Simulator) with an Incorrect Authorization weakness (CWE-863) that could allow authentication bypass by overwriting memory via a debugger. Affected software is EcoStruxure Control Expert (Unity Pro) across all versions; the...

7.8CVSS7.7AI score0.00327EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.26 views

CVE-2020-28211

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause bypass of authentication when overwriting memory using a debugger...

7.8AI score0.00327EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2020/11/19 12:0 a.m.12 views

PT-2020-6317 · Schneider Electric · Ecostruxure Control Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert all versions Description: The issue is related to the lack of restrictions on authentication attempts, which could allow a remote attacker to bypass the authentication procedure. This vulnerability may lead to...

9.8CVSS9.6AI score0.02757EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.14 views

Schneider Electric Unity Pro 安全漏洞

Schneider Electric EcoStruxure Control Expert is the universal programming, commissioning and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A command execution vulnerability exists in Schneider Electric EcoStruxure Control Expert. The vulnerability...

8.8CVSS7.6AI score0.01178EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.16 views

Schneider Electric EcoStruxure Control Expert 授权问题漏洞

EcoStruxure Control Expert is the universal programming, debugging and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A security vulnerability exists in PLC Simulator in EcoStruxure Control Expert. The vulnerability can be exploited by an attacker to...

9.8CVSS7.3AI score0.02757EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.12 views

Schneider Electric EcoStruxure Operator Terminal Expert Permission License and Access Control Issues Vulnerability

Schneider Electric EcoStruxure Operator Terminal Expert is a touch screen configuration software from Schneider Electric, France. This software branch is primarily used to create and edit touch applications. EcoStruxure Operator Terminal Expert suffers from a privilege license and access control...

7.8CVSS7.1AI score0.00313EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.14 views

Schneider Electric EcoStruxure Control Expert Security Vulnerability

Schneider Electric EcoStruxure Control Expert formerly known as Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A security vulnerability exists in EcoStruxure Control Expert that stems from a specially crafted request...

7.5CVSS7.1AI score0.01905EPSS
SaveExploits1References3
NCSC
NCSC
added 2020/11/13 12:0 a.m.13 views

Vulnerability fixed in EcoStruxure Control Expert

A vulnerability has been fixed that could cause a crash of the PLC simulator in EcoStruxure Control Expert software when a specially crafted request is received via Modbus. Schneider Electric has made available a firmware update that fixes the vulnerability. For more information, see:...

7.5CVSS6.9AI score0.01288EPSS
SaveExploits0
ThreatPost
ThreatPost
added 2020/11/12 4:52 p.m.22 views

Bugs in Critical Infrastructure Gear Allow Sophisticated Cyberattacks

Two security vulnerabilities in Schneider Electric’s programmable logic controllers PLCs could allow attackers to compromise a PLC and move on to more sophisticated critical infrastructure attacks. PLCs are key pieces of equipment in environments such as electric utilities and factories. They...

0.4AI score
SaveExploits0References11
CNVD
CNVD
added 2020/11/12 12:0 a.m.18 views

Schneider Electric EcoStruxure Control Expert PLC Denial of Service Vulnerability

Schneider Electric EcoStruxure Control Expert formerly Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A denial of service vulnerability exists in EcoStruxure Control Expert's PLC simulator, which originates when a...

7.5CVSS6.7AI score0.01288EPSS
SaveExploits0References1
ICS
ICS
added 2020/11/10 12:0 a.m.78 views

Schneider Electric PLC Simulator for EcoStruxure Control Expert

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: PLC Simulator for EcoStruxure Control Expert Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this...

7.5CVSS7.8AI score0.01288EPSS