Successful exploitation of these vulnerabilities could allow remote code execution.
The following versions of Struxureware Data Center Expert, a monitoring software, are affected:
The affected product is vulnerable to an OS command injection, which may allow an attacker to remotely execute code over the network.
CVE-2021-22795 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).
The affected product is vulnerable to directory traversal, which may allow an attacker to remotely execute code.
CVE-2021-22794 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).
David Yesland, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to Schneider Electric.
Schneider Electric has established a remediation plan for future versions of StruxureWare Data Center Expert to fix these vulnerabilities. Until the fix is released, users should immediately follow the security hardening guidelines found in Schneider Electric’s Data Center Expert Security Handbook to reduce the risk of exploit.
Schneider Electric has released security advisory SEVD-2021-257-03 in response to these vulnerabilities.
Schneider Electric strongly recommends the following industry cybersecurity best practices:
For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For more details and assistance on how to protect a user’s installation, contact the local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services.
For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22794
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22795
cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-03
cwe.mitre.org/data/definitions/22.html
cwe.mitre.org/data/definitions/78.html
dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook
download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
twitter.com/CISAgov
twitter.com/intent/tweet?text=Schneider%20Electric%20Struxureware%20Data%20Center%20Expert+https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-03
us-cert.cisa.gov/ics
us-cert.cisa.gov/ics
us-cert.cisa.gov/ics/recommended-practices
us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B
us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-03&title=Schneider%20Electric%20Struxureware%20Data%20Center%20Expert
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-03
www.oig.dhs.gov/
www.se.com/us/en/download/document/7EN52-0390/
www.se.com/us/en/work/support/cybersecurity/overview.jsp
www.se.com/ww/en/work/solutions/cybersecurity/
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Schneider%20Electric%20Struxureware%20Data%20Center%20Expert&body=www.cisa.gov/news-events/ics-advisories/icsa-21-257-03
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
82.3%