Lucene search
+L

186 matches found

CNVD
CNVD
•added 2016/09/06 12:00 a.m.•17 views

Siemens SIPROTEC 4/SIPROTEC Compact Denial of Service Vulnerability

SIPROTEC 4 and SIPROTEC Compact devices provide a wide range of centralized protection, control and automation functions for substations and other applications. A denial of service vulnerability exists in Siemens SIPROTEC 4, SIPROTEC Compact devices, versions prior to EN100 Ethernet 4.29. A remot...

7.8CVSS6.8AI score0.03002EPSS
SaveExploits0References1
ICS
ICS
•added 2016/06/10 6:00 a.m.•68 views

Siemens SIPROTEC 4 and SIPROTEC Compact Vulnerabilities

OVERVIEW Siemens reports that they have released a firmware update for SIPROTEC 4 and SIPROTEC Compact devices to mitigate authentication bypass and resource exhaustion vulnerabilities. Kirill Nesterov and Anatoly Katushin from Kaspersky Lab reported some of these vulnerabilities directly to...

10CVSS9.4AI score0.03002EPSS
SaveExploits0References10
OSV
OSV
•added 2016/05/31 1:59 a.m.•10 views

CVE-2016-4785

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS5.8AI score0.02676EPSS
SaveExploits0References6
OSV
OSV
•added 2016/05/31 1:59 a.m.•6 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS5.7AI score0.02676EPSS
SaveExploits0References6
NVD
NVD
•added 2016/05/31 1:59 a.m.•30 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6AI score0.02676EPSS
SaveExploits0References6
Prion
Prion
•added 2016/05/31 1:59 a.m.•20 views

Design/Logic Flaw

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5CVSS6.9AI score0.02676EPSS
SaveExploits0References6Affected Software1
Prion
Prion
•added 2016/05/31 1:59 a.m.•23 views

Design/Logic Flaw

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5CVSS6.6AI score0.02676EPSS
SaveExploits0References6Affected Software1
CVE
CVE
•added 2016/05/31 1:00 a.m.•67 views

CVE-2016-4785

SiemenS SIPROTEC 4/Compact EN100 Ethernet modules are affected by CVE-2016-4785. The integrated web server (port 80) could disclose a limited amount of device memory content to remote attackers with network access, and the issue only affects EN100 Ethernet modules inside SIPROTEC4 and SIPROTEC Co...

5.3CVSS6.8AI score0.02676EPSS
SaveExploits0References6Affected Software1
Cvelist
Cvelist
•added 2016/05/31 1:00 a.m.•34 views

CVE-2016-4785

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5AI score0.02676EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2016/05/31 1:00 a.m.•35 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5AI score0.02676EPSS
SaveExploits0References6
CVE
CVE
•added 2016/05/31 1:00 a.m.•76 views

CVE-2016-4784

CVE-2016-4784 affects Siemens SIPROTEC SIPROTEC 4/Compact devices with EN100 Ethernet module and SIPROTEC Merging Unit 6MU80. The vulnerability is information disclosure via the integrated web server (port 80) when network access is possible, allowing remote attackers to obtain sensitive device i...

5.3CVSS6.7AI score0.02676EPSS
SaveExploits0References6Affected Software1
Positive Technologies
Positive Technologies
•added 2016/05/31 12:00 a.m.•3 views

PT-2016-6138

Name of the Vulnerable Software and Affected Versions EN100 Ethernet module firmware variant PROFINET IO versions prior to V1.04.01 EN100 Ethernet module firmware variant Modbus TCP versions prior to V1.11.00 EN100 Ethernet module firmware variant DNP3 TCP versions prior to V1.03 EN100 Ethernet...

5.3CVSS0.02676EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2016/05/31 12:00 a.m.•4 views

PT-2016-6139

Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...

5.3CVSS0.02676EPSS
SaveExploits0References8
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/05/31 12:00 a.m.•8 views

CVE-2016-4785: Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6.3AI score0.02676EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/05/31 12:00 a.m.•7 views

CVE-2016-4784: Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6.3AI score0.02676EPSS
SaveExploits0References2
ICS
ICS
•added 2016/02/20 7:00 a.m.•67 views

Siemens SIPROTEC Information Disclosure Vulnerabilities (Update B)

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Siemens Equipment : SIPROTEC 4 and SIPROTEC Compact Vulnerabilities : Information Exposure 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-16-140-02...

5.3CVSS8AI score0.02676EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
•added 2015/12/17 12:00 a.m.•3 views

PT-2015-3361

Name of the Vulnerable Software and Affected Versions DIGSI 4 versions prior to V4.92 EN100 Ethernet module DNP3 variant versions prior to V1.05.00 EN100 Ethernet module IEC 104 variant all versions EN100 Ethernet module IEC 61850 variant versions prior to V4.30 EN100 Ethernet module Modbus TCP...

7.5CVSS0.01777EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2015/12/17 12:00 a.m.•4 views

PT-2015-3360

Name of the Vulnerable Software and Affected Versions EN100 Ethernet module IEC 61850 variant versions prior to V4.30 EN100 Ethernet module DNP3 variant versions prior to V1.04 EN100 Ethernet module PROFINET IO variant all versions EN100 Ethernet module Modbus TCP variant all versions EN100...

7.5CVSS0.01404EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2015/12/17 12:00 a.m.•17 views

PT-2018-05: Unauthorized Firmware Modification in Siemens EN100 Ethernet modules

The specialists of the Positive Research center have detected an Unauthorized Firmware Modification vulnerability in Siemens EN100 Ethernet modules. Vulnerability allows unauthenticated attackers to upgrade or downgrade the firmware of the affected device including to older versions with known...

7.5CVSS7.7AI score0.01404EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2015/12/17 12:00 a.m.•24 views

PT-2018-03: Control Takeover in Siemens DIGSI 4 and EN100 Ethernet modules

The specialists of the Positive Research center have detected a Control Takeover vulnerability in Siemens DIGSI 4 and EN100 Ethernet modules. Vulnerability allows unauthenticated remote, low-skilled attackers to upload a modified device configuration overwriting access authorization passwords, an...

10CVSS7.8AI score0.01777EPSS
SaveExploits0References5
Rows per page
Query Builder