155 matches found
CVE-2016-4784
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Design/Logic Flaw
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Design/Logic Flaw
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-4785
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-4785
SiemenS SIPROTEC 4/Compact EN100 Ethernet modules are affected by CVE-2016-4785. The integrated web server (port 80) could disclose a limited amount of device memory content to remote attackers with network access, and the issue only affects EN100 Ethernet modules inside SIPROTEC4 and SIPROTEC Co...
CVE-2016-4784
CVE-2016-4784 affects Siemens SIPROTEC SIPROTEC 4/Compact devices with EN100 Ethernet module and SIPROTEC Merging Unit 6MU80. The vulnerability is information disclosure via the integrated web server (port 80) when network access is possible, allowing remote attackers to obtain sensitive device i...
CVE-2016-4784
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC Information Disclosure Vulnerabilities (Update B)
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Siemens Equipment : SIPROTEC 4 and SIPROTEC Compact Vulnerabilities : Information Exposure 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-16-140-02...
PT-2018-05: Unauthorized Firmware Modification in Siemens EN100 Ethernet modules
The specialists of the Positive Research center have detected an Unauthorized Firmware Modification vulnerability in Siemens EN100 Ethernet modules. Vulnerability allows unauthenticated attackers to upgrade or downgrade the firmware of the affected device including to older versions with known...
PT-2018-03: Control Takeover in Siemens DIGSI 4 and EN100 Ethernet modules
The specialists of the Positive Research center have detected a Control Takeover vulnerability in Siemens DIGSI 4 and EN100 Ethernet modules. Vulnerability allows unauthenticated remote, low-skilled attackers to upload a modified device configuration overwriting access authorization passwords, an...
Siemens SIPROTEC 4和SIPROTEC Compact EN100模块拒绝服务漏洞
No description provided by source...
Siemens multiple products there is a security problem, the part of the patch has been released-vulnerability warning-the black bar safety net
Siemens recently released software and firmware security update, saying the company multiple products there are security issues, users are advised to update ASAP. ICS-CERT and Siemens announcement that the SIPROTEC 4 and SIPROTEC Compact devices recently have been affected by the vulnerability...
CVE-2015-5374
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2015-5374
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC Denial-of-Service Vulnerability
OVERVIEW Siemens has identified a denial-of-service vulnerability in the SIPROTEC 4 and SIPROTEC Compact devices. This vulnerability was reported directly to Siemens by Victor Nikitin from i‑Grids LLC Russia. Siemens has produced a new firmware update to mitigate this vulnerability. This...