Siemens Reyrolle
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Reyrolle Vulnerabilities: Missing Authorization, Improper Input Validation, Improper Authentication AFFECTED PRODUCTS Siemens reports that the vulnerabilities affect the following Reyrolle...
ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)
CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...
CVE-2016-7114
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7114
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Design/Logic Flaw
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7112
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Authentication flaw
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Authentication flaw
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
PT-2016-7224
Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...
PT-2016-7222
Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...
CVE-2016-7113
Siemens SIPROTEC 4/Compact EN100 Ethernet module vulnerabilities include CVE-2016-7113 (IMPROPER INPUT VALIDATION) where specially crafted packets to Port 80/TCP may cause the EN100 module to enter defect mode. Affected firmware variants are PROFINET IO (< V1.04.01), Modbus TCP (< V1.10.01/...
CVE-2016-7114: Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7112: Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113: Undefined Security Weakness
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
PT-2016-7223
Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...
CVE-2016-7112
CVE-2016-7112 is an Authentication Bypass vulnerability in the Siemens EN100 Ethernet module used with SIPROTEC 4/Compact and related equipment. Affected firmware variants PROFINET IO, Modbus TCP, DNP3 TCP, and IEC 104 in all SIPROTEC 4/Compact deployments allow remote attackers with access to th...
CVE-2016-7112
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7114
Siemens SIPROTEC 4/Compact EN100 Ethernet module family is affected by CVE-2016-7114 (Improper Authentication). The vulnerability allows remote attackers with network access to the device web interface (port 80) to possibly circumvent authentication and perform administrative operations, requirin...