31769 matches found
PT-2025-48772
Name of the Vulnerable Software and Affected Versions Longwatch version 6.309 Description A flaw in Longwatch devices permits unauthenticated HTTP GET requests to execute arbitrary code through an exposed endpoint. This is due to the lack of code signing and execution controls, leading to...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2023-52917)
ntb: intel: Fix the NULL vs ISERR bug for debugfscreatedir. The debugfscreatedir function returns error pointers. It never returns NULL. So use ISERR to check it. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
METZ CONNECT多款产品 安全漏洞
METZ CONNECT Energy-Controlling EWIO2-M and others are products of METZ CONNECT, Germany.METZ CONNECT Energy-Controlling EWIO2-M is a high performance data logger.METZ CONNECT Energy- Controlling EWIO2-M-BM is a high performance data logger.METZ CONNECT Ethernet-IO EWIO2-BM is a sensor and actuat...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56562)
i3c: master: miss free initdynaddr at i3cmasterputi3caddrs. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504562; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50082)
blk-rq-qos: vulnerability in blk-rq-qos can cause a crash due to a race condition between rqqoswait and rqqoswakefunction, which is fixed by ensuring the waitqueue entry is accessed in the correct order. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40983)
tipc: possible crash before doing decryption. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504584; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56724)
mfd: intelsocpmicbxtwc: Use IRQ domain for TMU device. While design wise the idea of converting the driver to use the hierarchy of the IRQ chips is correct, the implementation has inherited vulnerability. This was unveiled when platformgetirq had started WARN on IRQ 0 that is supposed to be a Lin...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53052)
iouring/rw: vulnerability due to iouring not checking for IOCBNOWAIT when starting an ODIRECT write, leading to potential deadlocks if the mount point is being frozen. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53239)
ALSA: 6fire: The current 6fire code tries to release the resources right after the call of usb6firechipabort. But at this moment, the card object might be still in use as we're calling sndcardfreewhenclosed and cause potential UAFs. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-47669)
nilfs2: state management vulnerability in error path of log writing function. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504649;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53184)
um: ubd: The drvdata is not available in release. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504490; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50268)
usb: typec: fix potential out of bounds in ucsiccgupdatesetnewcamcmd. The cmd variable can be controlled by the user via debugfs. That means newcam can be as high as 255 while the size of the uc-updated array is UCSIMAXALTMODES 30. The call tree is: ucsicmd // val comes from simpleattrwritexsigne...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53104)
media: uvcvideo: Skip parsing frames of type UVCVSUNDEFINED in uvcparseformat This can lead to out of bounds writes since frames of this type were not taken into account when calculating the size of the frames buffer in uvcparsestreaming. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56701)
powerpc/pseries: The dtlaccesslock needs to be a rwsempahore, a sleeping lock, because the code calls kmalloc while holding it, which can sleep. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, In...
Siemens SCALANCE and RUGGEDCOM Devices Improper Locking (CVE-2024-44952)
driver core: vulnerability due to a potential deadlock due to improper handling of device attributes and driver detachment, which has been fixed by using synchronizercu to prevent race conditions. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56739)
rtc: check if rtcreadtime was successful in rtctimerdowork If the rtcreadtime call fails, the struct rtctime tm; may contain uninitialized data, or an illegal date/time read from the RTC hardware. When calling rtctmtoktime later, the result may be a very large value possibly KTIMEMAX. If there ar...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46755)
wifi: mwifiex: Do not return unused priv in mwifiexgetprivbyid. mwifiexgetprivbyid returns the priv pointer corresponding to the bssnum and bsstype, but without checking if the priv is actually currently in use. Unused priv pointers do not have a wiphy attached to them which can lead to NULL...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53183)
um: net: The drvdata is not available in release. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504558; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56619)
nilfs2: When searching for records in a directory where the inode's isize is corrupted and has a large value, memory access outside the folio/page range may occur, or a use-after-free bug may be detected if KASAN is enabled. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49957)
ocfs2: null-ptr-deref when journal load failed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504593; scriptversion"1.2";...