Siemens SCALANCE and RUGGEDCOM Devices Improper Locking (CVE-2024-44952)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 4 Views

Siemens SCALANCE and RUGGEDCOM devices improper locking CVE-2024-44952 fixed by synchronize_rcu.

Related
Refs
Code
ReporterTitlePublishedViews
Family
cbl_mariner
CBLMariner
CVE-2024-44952 affecting package kernel for versions less than 5.15.167.1-1
12 Oct 202402:07
cbl_mariner
circl
Circl
CVE-2024-44952
4 Sep 202421:56
circl
cnnvd
CNNVD
编号撤回
4 Sep 202400:00
cnnvd
cve
CVE
CVE-2024-44952
4 Sep 202418:35
cve
cvelist
Cvelist
CVE-2024-44952
4 Sep 202418:35
cvelist
debian
Debian
[SECURITY] [DLA 3912-1] linux security update
7 Oct 202418:20
debian
debiancve
Debian CVE
CVE-2024-44952
4 Sep 202418:35
debiancve
nessus
Tenable Nessus
Debian dla-3912 : ata-modules-5.10.0-29-armmp-di - security update
7 Oct 202400:00
nessus
nessus
Tenable Nessus
EulerOS 2.0 SP9 : kernel (EulerOS-SA-2025-1040)
14 Jan 202500:00
nessus
nessus
Tenable Nessus
CBL Mariner 2.0 Security Update: kernel (CVE-2024-44952)
13 Oct 202400:00
nessus
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504707);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");

  script_cve_id("CVE-2024-44952");
  script_xref(name:"ICSA", value:"25-226-07");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Locking (CVE-2024-44952)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"driver core: vulnerability due to a potential deadlock due to improper
handling of device attributes and driver detachment, which has been
fixed by using synchronize_rcu() to prevent race conditions.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-44952");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(667);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
        {"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xcm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xch-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrh-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation