703 matches found
CVE-2021-3616
A vulnerability was reported in Lenovo Smart Camera X3, X5, and C2E that could allow an unauthorized user to view device information, alter firmware content and device configuration. This vulnerability is the same as CNVD-2020-68651...
Design/Logic Flaw
A vulnerability was reported in Lenovo Smart Camera X3, X5, and C2E that could allow an unauthorized user to view device information, alter firmware content and device configuration. This vulnerability is the same as CNVD-2020-68651...
CVE-2021-3616
CVE-2021-3616 affects Lenovo Smart Camera X3, X5, and C2E. The entry describes an unauthorized user able to view device information and alter firmware content and device configuration. The provided materials do not specify root cause details beyond the high/critical risk ratings and do not includ...
CVE-2021-3459
A privilege escalation vulnerability was reported in the MM1000 device configuration web server, which could allow privileged shell access and/or arbitrary privileged commands to be executed on the adapter...
rConfig SQL Injection Vulnerability (CNVD-2021-61756)
rConfig is an open source network device configuration management utility. rConfig version 3.9.5 is vulnerable to a SQL injection vulnerability that stems from an unvalidated dbName parameter in ajaxDbInstall.php, which can be exploited by attackers to access sensitive database information...
CVE-2021-31894
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier All versions, SIMATIC PCS 7 V9.X All versions V9.1 SP2, SIMATIC PDM All versions V9.2 SP2, SIMATIC STEP 7 V5.X All versions V5.7, SINAMICS STARTER containing STEP 7 OEM version All versions V5.4 SP2 HF1. A directory containing...
PT-2021-11518 · Siemens +1 · Development Evaluation Kits For Profinet Io Dk Standard Ethernet Controller +178
Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned. Description: The issue allows an unauthenticated attacker to trigger a denial of service condition by sending a large amount of DCP reset packets to the device. Recommendations: At the moment,...
Improper access control
Improper access in Notification setting prior to SMR JUN-2021 Release 1 allows physically proximate attackers to set arbitrary notification via physically configuring device...
CVE-2021-25409
Improper access in Notification setting prior to SMR JUN-2021 Release 1 allows physically proximate attackers to set arbitrary notification via physically configuring device...
Schneider Electric EnerlinÕX ComÕX 安全漏洞
The Schneider Electric EnerlinÕX ComÕX is a compact plug-and-play gateway and data logger from Schneider Electric France that is an essential component of an entry-level energy management system. A security vulnerability exists in the Schneider Electric EnerlinÕX ComÕX 510 that stems from an...
TP-Link TL-SG2005和TP-Link TL-SG2008 输入验证错误漏洞
Tp-link TP-Link TL-SG2005 and TP-Link TL-SG2008 are both switches from Tp-link. A security vulnerability exists in TP-Link TL-SG2005 and TL-SG2008. The vulnerability originates from version 1.0.0 of TL-SG2005 and TL-SG2008, which is affected by an array indexing error, whereby the interfaces that...
Vulnerability fixed in Schneider Electric Modicon
A vulnerability has been found in the firmware of Schneider Electric Modicon X80 devices. A malicious party can exploit the exploit the vulnerability to obtain configuration data from the device. To do this, a malicious person must make a rogue request towards the web server of the system. It is...
CVE-2020-27185
Cleartext transmission of sensitive information via Moxa Service in NPort IA5000A series serial devices. Successfully exploiting the vulnerability could enable attackers to read authentication data, device configuration, and other sensitive data transmitted over Moxa Service...
CVE-2020-27185
Cleartext transmission of sensitive information via Moxa Service in NPort IA5000A series serial devices. Successfully exploiting the vulnerability could enable attackers to read authentication data, device configuration, and other sensitive data transmitted over Moxa Service...
CVE-2020-27149
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
CVE-2021-1284
A vulnerability in the web-based messaging service interface of Cisco SD-WAN vManage Software could allow an unauthenticated, adjacent attacker to bypass authentication and authorization and modify the configuration of an affected system. To exploit this vulnerability, the attacker must be able t...
CVE-2020-35756
An issue was discovered on Libre Wireless LS9 LS1.5/p7040 devices. There is a luciservice GETPASS Configuration Password Information Leak. The luciservice daemon running on port 7777 does not require authentication to return the device configuration password in cleartext when using the GETPASS...
CVE-2020-35756
An issue was discovered on Libre Wireless LS9 LS1.5/p7040 devices. There is a luciservice GETPASS Configuration Password Information Leak. The luciservice daemon running on port 7777 does not require authentication to return the device configuration password in cleartext when using the GETPASS...
CVE-2021-20091
The web interfaces of Buffalo WSR-2533DHPL2 firmware version = 1.02 and WSR-2533DHP3 firmware version = 1.24 do not properly sanitize user input. An authenticated remote attacker could leverage this vulnerability to alter device configuration, potentially gaining remote code execution...
PT-2021-2825 · Cisco · Cisco Firepower Management Center
Name of the Vulnerable Software and Affected Versions: Cisco Firepower Management Center FMC Software affected versions not specified Description: The issue is related to insufficient enforcement of access control in the affected software, allowing an authenticated, remote attacker to access...