Lucene search
+L

703 matches found

Positive Technologies
Positive Technologies
added 2022/10/27 12:0 a.m.7 views

PT-2022-7009 · Cisco · Cisco Ios Xe +1

Name of the Vulnerable Software and Affected Versions: Cisco IOS Software and Cisco IOS XE Software affected versions not specified Description: A vulnerability in the Authentication, Authorization, and Accounting AAA feature could allow an authenticated, remote attacker to bypass command...

9.1CVSS7.3AI score0.00586EPSS
SaveExploits0References13
CNNVD
CNNVD
added 2022/10/04 12:0 a.m.8 views

Buffalo network devices 信任管理问题漏洞

Buffalo firmware is a network device from Buffalo, a Japanese company. Buffalo Wi-Fi devices are vulnerable to a trust management issue that stems from the use of hard-coded credentials, which can be exploited by an attacker on a neighboring network to modify the device's configuration...

6.5CVSS6.8AI score0.00244EPSS
SaveExploits0References4
NVD
NVD
added 2022/06/28 1:15 p.m.23 views

CVE-2022-29519

Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware...

7.9CVSS0.00377EPSS
SaveExploits0References4
Prion
Prion
added 2022/06/28 1:15 p.m.25 views

Design/Logic Flaw

Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware...

7.9CVSS7.3AI score0.00377EPSS
SaveExploits0References4Affected Software2
CVE
CVE
added 2022/06/28 10:5 a.m.87 views

CVE-2022-29519

CVE-2022-29519 affects Yokogawa STARDOM FCN/FCJ controllers (R1.01–R4.31; dual CPU modules R4.10–R4.31) and involves cleartext transmission of sensitive information, enabling an adjacent attacker to read/alter configuration or tamper firmware. The issue is complemented by CVE-2022-30997 (hard-cod...

7.9CVSS7.3AI score0.00377EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2022/06/28 10:5 a.m.37 views

CVE-2022-29519

Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware...

7.5AI score0.00377EPSS
SaveExploits0References4
ATTACKERKB
ATTACKERKB
added 2022/06/14 10:15 a.m.4 views

CVE-2022-32258

A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.1. The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure...

7.5CVSS5.4AI score0.00846EPSS
SaveExploits0References3
OSV
OSV
added 2022/06/14 10:15 a.m.7 views

CVE-2022-32258

A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.1. The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure...

7.5CVSS7AI score0.00846EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/06/14 10:10 a.m.26 views

CVE-2021-30281

Possible unauthorized access to secure space due to improper check of data allowed while flashing the no access control device configuration in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Voice & Music, Snapdragon...

8.4CVSS8.5AI score0.00159EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/06/14 12:0 a.m.14 views

PT-2022-21183 · Siemens · Sinema Remote Connect Server

Name of the Vulnerable Software and Affected Versions: SINEMA Remote Connect Server versions prior to V3.1 Description: A vulnerability has been identified in the affected application, which contains an older feature that allows importing device configurations via a specific endpoint. An attacker...

7.5CVSS6.6AI score0.00846EPSS
SaveExploits0References4
NVD
NVD
added 2022/06/13 6:15 p.m.46 views

CVE-2022-33175

Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...

9.8CVSS0.01733EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2022/03/31 12:0 a.m.7 views

GE General Electric Renewable Energy MDS Radios 安全漏洞

GE General Electric Renewable Energy MDS Radios is a series of industrial wireless solutions from General Electric GE. GE General Electric Renewable Energy MDS iNET/iNET II/SD/TD220/TD220MAX Radios.A security vulnerability exists in the iNET/iNET II series Radios that stems from allowing...

9.8CVSS8.2AI score0.00728EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.21 views

Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Missing Authentication For Critical Function (CVE-2018-4840)

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

7.5CVSS7.4AI score0.01811EPSS
SaveExploits0References3
NVD
NVD
added 2022/02/02 1:15 p.m.19 views

CVE-2022-22509

In Phoenix Contact FL SWITCH Series 2xxx in version 3.00 an incorrect privilege assignment allows an low privileged user to enable full access to the device configuration...

9CVSS0.0099EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/02 1:15 p.m.9 views

CVE-2022-22509

In Phoenix Contact FL SWITCH Series 2xxx in version 3.00 an incorrect privilege assignment allows an low privileged user to enable full access to the device configuration...

8.8CVSS7.3AI score0.0099EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2022/02/02 12:0 a.m.8 views

Phoenix Contact FL SWITCH 安全漏洞

The Phoenix Contact FL SWITCH is an industrial grade Ethernet switch from Phoenix Contact, Germany. A security vulnerability exists in the Phoenix Contact FL SWITCH Series that originates from allowing a user with low privileges to enable full access to the device configuration...

9CVSS7.9AI score0.0099EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2022/01/27 3:0 p.m.5 views

CVE-2021-44793

Single Connect does not perform an authorization check when using the sc-reports-ui" module. A remote attacker could exploit this vulnerability to access the device configuration page and export the data to an external file. The exploitation of this vulnerability might allow a remote attacker to...

8.6CVSS7.4AI score0.01367EPSS
SaveExploits0References3
Prion
Prion
added 2022/01/27 1:15 p.m.22 views

Authorization

Single Connect does not perform an authorization check when using the sc-reports-ui" module. A remote attacker could exploit this vulnerability to access the device configuration page and export the data to an external file. The exploitation of this vulnerability might allow a remote attacker to...

5CVSS8.4AI score0.01367EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/01/27 12:27 p.m.40 views

CVE-2021-44793 Information Leakege via Unauthorized Access in Single Connect

Single Connect does not perform an authorization check when using the sc-reports-ui" module. A remote attacker could exploit this vulnerability to access the device configuration page and export the data to an external file. The exploitation of this vulnerability might allow a remote attacker to...

8.6CVSS8.7AI score0.01367EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/01/27 12:0 a.m.6 views

PT-2022-12234

Name of the Vulnerable Software and Affected Versions Single Connect affected versions not specified Description The issue arises from the lack of an authorization check in the sc-reports-ui module, allowing a remote attacker to access the device configuration page and export data to an external...

8.6CVSS7.3AI score0.01367EPSS
SaveExploits0References7
Rows per page
Query Builder