Lucene search
+L

425 matches found

Cvelist
Cvelist
•added 2022/12/02 12:00 a.m.•49 views

CVE-2022-45480

PC Keyboard WiFi & Bluetooth allows an attacker in a man-in-the-middle position between the server and a connected device to see all data including keypresses in cleartext. CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N...

5.8AI score0.00397EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2022/11/23 4:48 p.m.•12 views

CVE-2021-35246 Unprotected Transport of Credentials (HSTS) Vulnerability

The application fails to prevent users from connecting to it over unencrypted connections. An attacker able to modify a legitimate user's network traffic could bypass the application's use of SSL/TLS encryption and use the application as a platform for attacks against its users...

5.3CVSS5.3AI score0.00365EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2022/09/06 6:15 p.m.•18 views

CVE-2022-23678

A vulnerability in the Aruba Virtual Intranet Access VIA client for Microsoft Windows operating system client communications that could allow for an attacker in a privileged network position to intercept sensitive information in Aruba Virtual Intranet Access VIA client for Microsoft Windows...

5.9CVSS5.6AI score0.00965EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2022/08/24 12:00 a.m.•28 views

Illumina Local Run Manager Auth Bypass

The vulnerability of the Illumina Local Run Manager software lies in the absence of an authentication process. Exploiting this vulnerability allows a malicious actor to remotely infiltrate, replicate, modify, and/or intercept sensitive data...

9.1CVSS8AI score0.01143EPSS
SaveExploits0References3Affected Software1
osv_cve
osv_cve
•added 2022/06/24 3:15 p.m.•22 views

CVE-2022-1521

LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data...

9.1CVSS5.8AI score0.01143EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/24 12:00 a.m.•7 views

CVE-2022-1521: Improper Access Control

LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data...

9.1CVSS8.4AI score0.01143EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2022/06/24 12:00 a.m.•25 views

PT-2022-4353 · Illumina · Illumina Local Run Manager

Name of the Vulnerable Software and Affected Versions: Illumina Local Run Manager affected versions not specified Description: The issue is related to the lack of authentication or authorization procedures in the software. This allows a malicious actor to inject, replay, modify, and/or intercept...

9.1CVSS9AI score0.01143EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2022/06/01 12:00 a.m.•19 views

Siemens SICAM P850/P855 Open Protocol Traffic Intercept Disruption

The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in the transmission of data in an open manner via the HTTP protocol. Exploiting this vulnerability can allow a remote attacker to intercept traffic and disrupt the operation of the device...

10CVSS7.4AI score0.00754EPSS
SaveExploits0References5Affected Software2
osv_cve
osv_cve
•added 2022/05/12 10:15 p.m.•24 views

CVE-2021-27768

Using the ability to perform a Man-in-the-Middle MITM attack, which indicates a lack of hostname verification, sensitive account information was able to be intercepted. In this specific scenario, the application's network traffic was intercepted using a proxy server set up in 'transparent' mode...

5.9CVSS6.2AI score0.00329EPSS
SaveExploits0References1
osv_usn
osv_usn
•added 2022/03/31 6:51 p.m.•28 views

USN-5360-1 tomcat9 vulnerabilities

It was discovered that Tomcat incorrectly performed input verification. A remote attacker could possibly use this issue to intercept sensitive information. CVE-2020-13943, CVE-2020-17527, CVE-2021-25122, CVE-2021-30640 It was discovered that Tomcat did not properly deserialize untrusted data. An...

7.5CVSS7.2AI score0.74667EPSS
SaveExploits19References10
Positive Technologies
Positive Technologies
•added 2022/03/18 12:00 a.m.•20 views

PT-2022-8710 · Ge · Ge Reason Rt430 +2

Name of the Vulnerable Software and Affected Versions: GE Reason RT430, RT431 & RT434 GNSS clocks versions prior to 08A06 Description: The issue allows attackers to intercept and decrypt encrypted traffic through an HTTPS connection by having access to the hard-coded cryptographic key. This could...

5.3CVSS5.2AI score0.00859EPSS
SaveExploits0References4
NVD
NVD
•added 2021/12/01 4:15 p.m.•55 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS0.00489EPSS
SaveExploits0References2
Prion
Prion
•added 2021/12/01 4:15 p.m.•32 views

Authentication flaw

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

4.8CVSS8AI score0.00489EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/12/01 3:38 p.m.•58 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

7.3CVSS8.1AI score0.00489EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/12/01 12:00 a.m.•13 views

CVE-2020-10627: Improper Access Control

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS5.9AI score0.00489EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/11/07 12:00 a.m.•22 views

IBM QRadar Network Security security vulnerabilities

IBM QRadar Network Security is a network security manager from IBM USA, Inc. used to provide better visibility and control over activities and users on the network, while using deep packet inspection, heuristics and behavior-based analysis to detect and prevent advanced threats.A security...

6.8CVSS5.7AI score0.00589EPSS
SaveExploits0References5
Ivan 'd0znpp' Novikov
Ivan 'd0znpp' Novikov
•added 2021/08/27 1:34 p.m.•38 views

What is Eavesdropping Attack❓ Definition, Types and Prevention

Eavesdropping can be defined as the demonstration of quietly catching a discussion among arbitrary outsiders; albeit discourteous, what mischief might it actually do? All things considered, very little in case somebody is simply honestly paying attention to a discussion that intrigues them...

SaveExploits0
CNNVD
CNNVD
•added 2021/07/06 12:00 a.m.•25 views

Philips Vue PACS security vulnerabilities

Philips Vue PACS is an image management solution from Philips Europe. Philips Vue PACS suffers from a security vulnerability that arises from the software transmitting sensitive or security-critical data in clear text, a communication channel that can be sniffed by unauthorized actors...

7.5CVSS7.7AI score0.00644EPSS
SaveExploits0References4
ThreatPost
ThreatPost
•added 2021/05/18 6:36 p.m.•32 views

Stalkerware Apps Riddled with Security Bugs

Android stalkerware apps – used to surreptitiously track people’s movements and digital activities – turn out to themselves be rife with security holes that put victims in even danger. Stalkerware can track the GPS location of a victim’s device, record conversations, capture images and snoop on...

8.4AI score
SaveExploits0References6
VulnCheck KEV
VulnCheck KEV
•added 2021/04/02 12:00 a.m.•19 views

VulnCheck KEV: CVE-2019-5591

Fortinet FortiOS contains a default configuration vulnerability that may allow an unauthenticated attacker on the same subnet to intercept sensitive information by impersonating the Lightweight Directory Access Protocol LDAP server...

6.5CVSS7.1AI score0.18566EPSS
SaveIn wildExploits1References16
Rows per page
Query Builder