126 matches found
CVE-2025-41452 Post auth nginx configuration injection in Danfoss AK-SM8xxA Series
Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions...
CVE-2025-41452
Danfoss AK-SM8xxA Series before 4.3.1 contains a post-authenticated external control of the system Web interface configuration, with improper handling of exceptional conditions that could cause a DoS. CVSS 6.8 (Network, high attack complexity, high impact on availability). Remediation: update to ...
CVE-2025-41451 Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series
Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command 'Command Injection' in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system...
CVE-2025-41451
CVE-2025-41451 affects Danfoss AK-SM8xxA Series prior to version 4.3.1. Root cause: improper neutralization of alarm-to-mail configuration fields in an OS shell command, enabling post-authenticated remote code execution on the attacked system. Impact: remote code execution with high severity; att...
CVE-2025-41451 Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series
Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command 'Command Injection' in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system...
PT-2025-34328 · Danfoss · Ak-Sm8Xxa
Name of the Vulnerable Software and Affected Versions: Danfoss AK-SM8xxA Series versions prior to 4.3.1 Description: A post-authenticated external control of system web interface configuration setting issue exists. This could allow for a denial of service attack due to improper handling of...
PT-2025-34327 · Danfoss · Ak-Sm8Xxa
Name of the Vulnerable Software and Affected Versions: Danfoss AK-SM8xxA Series versions prior to 4.3.1 Description: Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command 'Command Injection' exists in the software, potentially leading to post-authenticated remo...
Danfoss AK-SM8xxA Series 安全漏洞
Danfoss AK-SM8xxA Series is a series of system-only managers from Danfoss, Denmark. A security vulnerability exists in Danfoss AK-SM8xxA Series versions prior to 4.3.1 that originates from improper neutralization and could lead to remote code execution...
Danfoss AK-SM8xxA Series 安全漏洞
Danfoss AK-SM8xxA Series is a series of system-only managers from Danfoss, Denmark. A security vulnerability exists in Danfoss AK-SM8xxA Series versions prior to 4.3.1, which stems from mishandling of exceptions and could result in a denial of service...
Danfoss AK-SM800A Improper Authentication (CVE-2025-41450)
Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive information such as internal IP addresses, usernames, store names and other sensitive information. This plugin only works with Tenable.ot. Please visit...
CVE-2023-22582
The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting...
CVE-2023-22583
The Danfoss AK-EM100 web forms allow for SQL injection in the login forms...
CVE-2023-22585
The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter...
CVE-2023-22584
The Danfoss AK-EM100 stores login credentials in cleartext...
CVE-2023-22586
The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter...
CISA Releases Thirteen Industrial Control Systems Advisories
CISA released thirteen Industrial Control Systems ICS advisories on May 20, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-140-01 ABUP IoT Cloud Platform ICSA-25-140-02 National Instruments Circuit Design Sui...
CVE-2025-41450
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2...
CVE-2025-41450
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2...
CVE-2025-41450 Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2...
CVE-2025-41450
Summary (CVE-2025-41450): Improper authentication in Danfoss AK-SM 8xxA Series (pre-4.2). Multiple sources confirm an authentication bypass that could enable remote access and potentially arbitrary action; CISA notes remote code execution risk. The issue affects AK-SM 8xxA Series prior to version...