179 matches found
CVE-2025-41450_poc
CVE-2025-41450 Danfoss AK-SM 800A Code-of-the-Day Authentication Bypass A Python proof of concept demonstrating a predictable code-of-the-day authentication mechanism exposed through the Danfoss system manager XML interface. The vulnerability may allow a remote, unauthenticated actor to derive a...
fromagegate
Danfoss AK-SM 8xxA — CVE-2025-41450 / -41451 / -41452 PoC toolkit Research/detection-engineering PoCs for the three AK-SM 8xxA web interface vulnerabilities disclosed by Claroty Team82 and fixed by Danfoss in R4.2 / R4.3.1 DSA-2025-03-01, DSA-2025-08-01, CISA ICSA-25-140-03: CVE| Weakness|...
CVE-2026-127057
The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected...
CVE-2026-129713
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver...
CVE-2026-127057 Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and AK-SM 800 Series
The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected...
CVE-2026-127057
The Danfoss legacy AK-SC 355 and AK-SM 800 Series products are vulnerable to unauthorized access because they were manufactured with default credentials documented in the product manual. This vulnerability affects all versions of these legacy systems. The root cause is the use of known passwords ...
EUVD-2026-131451
The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected...
EUVD-2026-131448
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver...
CVE-2026-129713 Stack-based buffer overflow in Danfoss AK-SM8xxA unauthenticated CGI handler
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver...
CVE-2026-129713
The Danfoss AK-SM 8xxA Series controller is vulnerable to a stack-based buffer overflow in an unauthenticated CGI handler. Remote attackers can exploit this by sending specially crafted HTTP/S POST requests , which may cause memory corruption, a webserver restart, and potentially arbitrary code e...
CVE-2026-127057: Danfoss: The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or…
The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected...
CVE-2026-129713: Danfoss AK-SM8xxA: A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows…
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver...
PT-2026-152866
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver...
PT-2026-152864
The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected...
France Blames Iran for Sabotage Attack on Refrigeration Controllers at About 700 Retail Sites
An October cyberattack on refrigeration controllers at about 700 French retail sites was carried out by a cyber unit of Iran's Islamic Revolutionary Guard Corps IRGC, the French government said yesterday. The attackers broke into controllers on the night of October 11 and changed their defrost...
Ole-K2-Danfoss-Firmware-Disclosure
Ole-K2 Danfoss Firmware Disclosure Researcher: Ole-k2 In...
New Wave of Refrigeration Cyberattacks Hits Supermarkets Across Europe, Forcing Stores to Pull Food
Attackers remotely changed the settings on refrigeration controls at supermarkets in Belgium, Sweden, Estonia and other European countries overnight into Monday, November 2, warming fridges and freezers. No chain reported more than several dozen affected stores, and some had to throw away chilled...
VulnCheck KEV: CVE-2025-41452
Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions...
VulnCheck KEV: CVE-2025-41451
Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command 'Command Injection' in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system...
PT-2026-115090
Attackers converted grocery store refrigeration systems into heating units, reaching 50°C 120°F across 400+ European stores. They exploited Internet-exposed Danfoss controllers via CVE-2024-41450/41451/41452, then moved laterally through OT networks to coordinate simultaneous temperature...