Lucene search
+L

1503 matches found

Vulnrichment
Vulnrichment
added 2024/11/15 11:2 a.m.14 views

CVE-2024-10534 Improper Access Control in Dataprom Informatics' PACS-ACSS

Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...

8.6CVSS5.8AI score0.00361EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2024/11/15 11:2 a.m.33 views

CVE-2024-10534 Improper Access Control in Dataprom Informatics' PACS-ACSS

Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...

8.6CVSS0.00361EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/11/15 12:0 a.m.14 views

Dataprom Informatics Personnel Attendance Control Systems (PACS)和Access Control Security Systems (ACSS) 访问控制错误漏洞

Access Control Security Systems ACSS and Dataprom Informatics Personnel Attendance Control Systems PACS are both products of Dataprom Informatics.Access Control Security Systems ACSS is a security access control system that is used to control and manage access to specific areas or...

9.8CVSS6.8AI score0.00361EPSS
SaveExploits0References1
CISA
CISA
added 2024/11/14 12:0 p.m.7 views

CISA Releases Nineteen Industrial Control Systems Advisories

CISA released nineteen Industrial Control Systems ICS advisories on November 14, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-319-01 Siemens RUGGEDCOM CROSSBOW ICSA-24-319-02 Siemens SIPORT ICSA-24-319-03...

6.9AI score
SaveExploits0References19
ICS
ICS
added 2024/11/14 7:0 a.m.11 views

2N Access Commander (Update A)

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate their privileges, execute arbitrary code, or gain root access to the system. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...

8.5AI score
SaveExploits0References10
ICS
ICS
added 2024/11/14 7:0 a.m.10 views

Rockwell Automation FactoryTalk Updater (Update A)

RISK EVALUATION Successful exploitation of these vulnerabilities could result in an authentication bypass, remote code execution, and/or a local privilege escalation 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...

8.3AI score
SaveExploits0References10
Circl
Circl
added 2024/11/13 5:47 a.m.6 views

CVE-2024-8933

creationtimestamp| type| source ---|---|--- 2024-11-13 05:47:58+00:00| seen| https://t.me/cvedetector/10791 2024-11-21 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-24-326-03 2026-04-14 13:10:17+00:00| seen| https://bsky.app/profile/o2cloud.bsky.social/post/3mjhhczv3a...

7.5CVSS4.8AI score0.00281EPSS
SaveExploits0References3
CISA
CISA
added 2024/11/12 12:0 p.m.4 views

CISA Releases Five Industrial Control Systems Advisories

CISA released five Industrial Control Systems ICS advisories on November 12, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-317-01 Subnet Solutions PowerSYSTEM Center ICSA-24-317-02 Hitachi Energy TRO600...

7AI score
SaveExploits0References5
ICS
ICS
added 2024/11/12 7:0 a.m.14 views

Rockwell Automation FactoryTalk View ME

RISK EVALUATION Successful exploitation of this vulnerability could allow a local low-privileged user to escalate their privileges by changing the macro to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...

7.8CVSS8.1AI score0.00226EPSS
SaveExploits0References10
ICS
ICS
added 2024/11/12 7:0 a.m.9 views

Subnet Solutions PowerSYSTEM Center

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause an integer overflow on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...

9.8CVSS8AI score0.01686EPSS
SaveExploits0References10
ICS
ICS
added 2024/11/12 12:0 a.m.20 views

Schneider Electric EcoStruxure IT Gateway

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

10CVSS6.7AI score0.00624EPSS
SaveExploits0References11
ICS
ICS
added 2024/11/12 12:0 a.m.19 views

Siemens SIMATIC CP

SUMMARY SIMATIC CP 1543-1 devices contain an Incorrect Authorization vulnerability that could allow an unauthenticated attacker to gain access to the filesystem. Siemens has released a new version for SIMATIC CP 1543-1 V4.0 and recommends to update to the latest version. 2. GENERAL...

8.7CVSS7.3AI score0.00471EPSS
SaveExploits0References10
ICS
ICS
added 2024/11/12 12:0 a.m.15 views

Siemens SCALANCE M-800 Family

SUMMARY SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network...

9.6AI score
SaveExploits0References10
BDU FSTEC
BDU FSTEC
added 2024/11/11 12:0 a.m.8 views

The vulnerability of Moxa EDS-P510 microcontroller software-related microprogramming systems, related to access control errors, allows attackers to escalate their privileges.

The vulnerability of Moxa EDS-P510 microcontroller software-related systems is related to errors in access control for the Modbus/TCP interface. Exploiting this vulnerability allows an attacker to enhance their privileges and alter the device’s functions in SCADA and DCS environments...

5.8CVSS5.5AI score
SaveExploits0References1Affected Software1
CISA
CISA
added 2024/11/07 12:0 p.m.6 views

CISA Releases Three Industrial Control Systems Advisories

CISA released three Industrial Control Systems ICS advisories on November 7, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-312-01 Beckhoff Automation TwinCAT Package Manager ICSA-24-312-02 Delta Electronics...

7AI score
SaveExploits0References3
ICS
ICS
added 2024/11/07 7:0 a.m.12 views

Bosch Rexroth IndraDrive

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...

7.5CVSS7.1AI score0.00495EPSS
SaveExploits0References10
ICS
ICS
added 2024/11/07 7:0 a.m.11 views

Beckhoff Automation TwinCAT Package Manager

RISK EVALUATION Successful exploitation this vulnerability could allow a local attacker with administrative access rights to execute arbitrary OS commands on the affected system. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...

6.5CVSS7.4AI score0.00189EPSS
SaveExploits0References10
Circl
Circl
added 2024/11/05 12:11 p.m.10 views

CVE-2024-47253

creationtimestamp| type| source ---|---|--- 2024-11-05 12:11:38+00:00| seen| https://t.me/cvedetector/9854 2024-11-14 12:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-17...

7.2CVSS4.8AI score0.00926EPSS
SaveExploits0References2
CISA
CISA
added 2024/10/31 12:0 p.m.10 views

CISA Releases Four Industrial Control Systems Advisories

CISA released four Industrial Control Systems ICS advisories on October 31, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-305-01 Rockwell Automation FactoryTalk ThinManager ICSA-24-030-02 Mitsubishi Electric...

7.1AI score
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2024/10/31 12:0 a.m.8 views

The vulnerability of Siemens SIMATIC STEP 7 Safety’s process control systems, related to the restoration of unreliable data in memory, allows a intruder to execute arbitrary code.

The vulnerability of Siemens SIMATIC STEP 7 Safety process control systems is related to the restoration of unreliable data in memory. Exploiting this vulnerability can allow an attacker to execute arbitrary code...

6.3CVSS7.5AI score0.00178EPSS
SaveExploits0References3
Rows per page