1488 matches found
CISA Releases One Industrial Control Systems Advisory
CISA released one Industrial Control Systems ICS advisory on November 19, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-324-01 Mitsubishi Electric MELSEC iQ-F Series CISA encourages users and administrators ...
Mitsubishi Electric MELSEC iQ-F Series (Update A)
RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service condition in Ethernet communication on the module. A system reset of the module is required for recovery. 2. RECOMMENDED PRACTICES CISA recommends users take defensive...
CVE-2024-10534
Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...
CVE-2024-10534
Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...
CVE-2024-10534
Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection.This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...
CVE-2024-10534 Improper Access Control in Dataprom Informatics' PACS-ACSS
Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...
CVE-2024-10534
CVE-2024-10534 affects Dataprom Informatics’ PACS/ACSS products, caused by an origin validation error that enables traffic injection. The vulnerability, described as an improper origin check affecting PACS/ACSS prior to 2024, is documented with high-severity impact (traffic manipulation). Connect...
CVE-2024-10534 Improper Access Control in Dataprom Informatics' PACS-ACSS
Origin Validation Error vulnerability in Dataprom Informatics Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS allows Traffic Injection. This issue affects Personnel Attendance Control Systems PACS / Access Control Security Systems ACSS: before 2024...
Dataprom Informatics Personnel Attendance Control Systems (PACS)和Access Control Security Systems (ACSS) 访问控制错误漏洞
Access Control Security Systems ACSS and Dataprom Informatics Personnel Attendance Control Systems PACS are both products of Dataprom Informatics.Access Control Security Systems ACSS is a security access control system that is used to control and manage access to specific areas or...
CISA Releases Nineteen Industrial Control Systems Advisories
CISA released nineteen Industrial Control Systems ICS advisories on November 14, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-319-01 Siemens RUGGEDCOM CROSSBOW ICSA-24-319-02 Siemens SIPORT ICSA-24-319-03...
2N Access Commander (Update A)
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate their privileges, execute arbitrary code, or gain root access to the system. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...
Rockwell Automation FactoryTalk Updater (Update A)
RISK EVALUATION Successful exploitation of these vulnerabilities could result in an authentication bypass, remote code execution, and/or a local privilege escalation 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...
CVE-2024-8933
creationtimestamp| type| source ---|---|--- 2024-11-13 05:47:58+00:00| seen| https://t.me/cvedetector/10791 2024-11-21 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-24-326-03 2026-04-14 13:10:17+00:00| seen| https://bsky.app/profile/o2cloud.bsky.social/post/3mjhhczv3a...
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on November 12, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-317-01 Subnet Solutions PowerSYSTEM Center ICSA-24-317-02 Hitachi Energy TRO600...
Rockwell Automation FactoryTalk View ME
RISK EVALUATION Successful exploitation of this vulnerability could allow a local low-privileged user to escalate their privileges by changing the macro to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...
Subnet Solutions PowerSYSTEM Center
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause an integer overflow on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...
Schneider Electric EcoStruxure IT Gateway
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Siemens SIMATIC CP
SUMMARY SIMATIC CP 1543-1 devices contain an Incorrect Authorization vulnerability that could allow an unauthenticated attacker to gain access to the filesystem. Siemens has released a new version for SIMATIC CP 1543-1 V4.0 and recommends to update to the latest version. 2. GENERAL...
Siemens SCALANCE M-800 Family
SUMMARY SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network...
The vulnerability of Moxa EDS-P510 microcontroller software-related microprogramming systems, related to access control errors, allows attackers to escalate their privileges.
The vulnerability of Moxa EDS-P510 microcontroller software-related systems is related to errors in access control for the Modbus/TCP interface. Exploiting this vulnerability allows an attacker to enhance their privileges and alter the device’s functions in SCADA and DCS environments...