8977 matches found
CVE-2020-9477
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker...
Authentication flaw
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker...
CVE-2020-9477
CVE-2020-9477 concerns HUMAX HGA12R-02 BRGCAA 1.1.53 devices where a flaw in the web-based authentication allows an unauthenticated remote attacker to capture authentication packets and obtain the cleartext password. This enables the attacker to create a new user account or take control of the de...
CVE-2020-9477
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker...
Moxa ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility Vulnerabilities: Cleartext Storage of Sensitive Information, Cleartext Transmission of Sensitive...
Moxa EDS-G516E and EDS-510E Series Ethernet Switches
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: EDS-G516E series, and EDS-510E series Vulnerabilities: Stack-based Buffer Overflow, Use of a Broken or Risky Cryptographic Algorithm, Use of Hard-coded Cryptographic Key, Use of...
Auto-Maskin RP210E, DCU210E, and Marine Observer Pro (Android App)
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Auto-Maskin Equipment: RP 210E Remote Panels, DCU 210E Control Units, and Marine Observer Pro Android App Vulnerabilities: Cleartext Transmission of Sensitive Information, Origin Validation Error,...
CVE-2020-3935
TAIWAN SECOM CO., LTD., a Door Access Control and Personnel Attendance Management system, stores users’ information by cleartext in the cookie, which divulges password to attackers...
CVE-2020-3935
TAIWAN SECOM CO., LTD., a Door Access Control and Personnel Attendance Management system, stores users’ information by cleartext in the cookie, which divulges password to attackers...
Default credentials
TAIWAN SECOM CO., LTD., a Door Access Control and Personnel Attendance Management system, stores users’ information by cleartext in the cookie, which divulges password to attackers...
CVE-2020-3935
CVE-2020-3935 concerns Taiwan SECOM’s Door Access Control and Personnel Attendance Management system, where user information is stored in cleartext in cookies, exposing passwords to attackers. The NVD and related records assign a CVSSv3.1 base score of 7.5 (HIGH) with NETWORK attack vector and no...
CVE-2020-3935 TAIWAN SECOM CO., LTD. – Sensitivity Information Exposure
TAIWAN SECOM CO., LTD., a Door Access Control and Personnel Attendance Management system, stores users’ information by cleartext in the cookie, which divulges password to attackers...
Nord Security: Hard-coded API keys at NordVpn Android App
Hello NordVpn, APK Version : 4.6.2 API'S at res/values/strings.xml Google googleapikey = AIzaSyBySEqk7WWee9bxpw5BM1eJeUx1TWdHE Stripe stripepublishableapikey = pklivej1Mt911wyZwAhATA9TYdA8q2 Referance; https://stripe.com/docs/keys Impact Cleartext Storage of Sensitive Information...
CVE-2017-18642
Syska Smart Bulb devices through 2017-08-06 receive RGB parameters over cleartext Bluetooth Low Energy BLE, leading to sniffing, reverse engineering, and replay attacks...
CVE-2017-18642
Syska Smart Bulb devices through 2017-08-06 receive RGB parameters over cleartext Bluetooth Low Energy BLE, leading to sniffing, reverse engineering, and replay attacks...
Code injection
Syska Smart Bulb devices through 2017-08-06 receive RGB parameters over cleartext Bluetooth Low Energy BLE, leading to sniffing, reverse engineering, and replay attacks...
CVE-2017-18642
CVE-2017-18642 affects Syska Smart Bulb devices up to 2017-08-06, where RGB parameters are transmitted over cleartext Bluetooth Low Energy (BLE). The underlying issue is unencrypted BLE traffic, enabling sniffing, reverse engineering, and replay attacks. Connected sources corroborate the BLE clea...
CVE-2017-18642
Syska Smart Bulb devices through 2017-08-06 receive RGB parameters over cleartext Bluetooth Low Energy BLE, leading to sniffing, reverse engineering, and replay attacks...
CVE-2019-20061
The user-introduction email in MFScripts YetiShare v3.5.2 through v4.5.4 may leak the system-picked password if this email is sent in cleartext. In other words, the user is not allowed to choose their own initial password...
CVE-2019-20061
The user-introduction email in MFScripts YetiShare v3.5.2 through v4.5.4 may leak the system-picked password if this email is sent in cleartext. In other words, the user is not allowed to choose their own initial password...