Lucene search
+L

7495 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/29 12:00 a.m.•7 views

CVE-2018-7790: Authentication Bypass by Capture-replay

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...

9.8CVSS7.3AI score0.02478EPSS
SaveExploits0References6
ThreatPost
ThreatPost
•added 2018/08/28 9:19 p.m.•25 views

Crashing Mobile Apps Capture Screens, Leak Private Data

Several mobile software developer kits SDKs can capture sensitive user data when a mobile app crashes, exposing private data to an outside third party. Researchers at Appthority singled out SDKs offered by AppSee and TestFairy in a report published Monday. They warned that mobile users whose apps...

0.1AI score
SaveExploits0References3
Kitploit
Kitploit
•added 2018/08/25 1:07 p.m.•51 views

Crypton - Library Consisting Of Explanation And Implementation Of All The Existing Attacks On Various Encryption Systems, Digital Signatures, Hashing Algorithms

Crypton is an educational library to learn and practice Offensive and Defensive Cryptography. It is basically a collection of explanation and implementation of all the existing vulnerabilities and attacks on various Encryption Systems Symmetric and Asymmetric, Digital Signatures, Message...

7.5AI score
SaveExploits0References116
Tenable Nessus
Tenable Nessus
•added 2018/08/24 12:00 a.m.•55 views

Ubuntu 14.04 LTS : Linux kernel vulnerabilities (USN-3754-1)

The remote Ubuntu 14.04 LTS host has a package installed that is affected by multiple vulnerabilities as referenced in the USN-3754-1 advisory. Ralf Spenneberg discovered that the ext4 implementation in the Linux kernel did not properly validate meta block groups. An attacker with physical access...

9.8CVSS7AI score0.05905EPSS
SaveExploits17References54
n0where
n0where
•added 2018/08/23 4:23 p.m.•37 views

Offensive and Defensive Cryptography: Crypton

Crypton is an educational library to learn and practice Offensive and Defensive Cryptography. It is basically a collection of explanation and implementation of all the existing vulnerabilities and attacks on various Encryption Systems Symmetric and Asymmetric, Digital Signatures, Message...

1.4AI score
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2018/08/23 12:00 a.m.•5 views

PT-2018-1983

Name of the Vulnerable Software and Affected Versions Astra Linux affected versions not specified Description The issue is related to errors in the security subsystem of the Fly-admin-dm utility in Astra Linux, allowing an attacker to capture screenshots of graphical windows containing confidenti...

6.8CVSS6AI score
SaveExploits0References1
ThreatPost
ThreatPost
•added 2018/08/22 2:58 p.m.•20 views

Triout Malware Carries Out Extensive, Targeted Android Surveillance

A mobile spyware for Android was disclosed today, with extensive, advanced surveillance capabilities that suggest that a sophisticated actor is pulling the strings. Using a recently discovered malware dubbed Triout, bad actors are tapping into the proliferating footprint of Android-based...

7.1AI score
SaveExploits0References2
CNVD
CNVD
•added 2018/08/14 12:00 a.m.•25 views

Multiple Medtronic Product Information Disclosure Vulnerabilities

Medtronic MMT-508 MiniMed insulin pump and others are different models of insulin pumps from Medtronic, USA. An information disclosure vulnerability exists in several Medtronic products, which can be exploited by an attacker to capture the information passed between the controller and pump when t...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2018/08/13 10:00 p.m.•46 views

CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.3AI score0.00712EPSS
SaveExploits0References3
CVE
CVE
•added 2018/08/13 10:00 p.m.•86 views

CVE-2018-14781

CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3Affected Software1
NVD
NVD
•added 2018/08/13 9:48 p.m.•36 views

CVE-2018-14781

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3
Prion
Prion
•added 2018/08/13 9:48 p.m.•31 views

Default configuration

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options...

2.9CVSS5.2AI score0.00712EPSS
SaveExploits0References2
Prion
Prion
•added 2018/08/13 9:47 p.m.•31 views

Information disclosure

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker cou...

2.9CVSS5.2AI score0.00474EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/13 12:00 a.m.•11 views

CVE-2018-14781: Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS6.3AI score0.00712EPSS
SaveExploits0References3
Trend Micro Simply Security
Trend Micro Simply Security
•added 2018/08/09 1:00 p.m.•52 views

Fighting the Skills Gap Via Industry Leading Research and Inspiring Events

By Kevin Simzer Among the headline-grabbing reports of election hacking, nation-state raids on utilities firms, and mega-data breaches, few outside the industry ask the question: Did the cybersecurity skills shortage play a part? It’s impossible to say for sure. However, what we do know is that...

0.2AI score
SaveExploits0
Typo3
Typo3
•added 2018/08/09 12:00 a.m.•24 views

Captcha bypass in extension "Front End User Registration" (sr_feuser_register)

When the extension is used together with the TYPO3 Extension srfreecap, it is possible to bypass the catcha in the registration form...

6.9AI score
SaveExploits0Affected Software1
Kitploit
Kitploit
•added 2018/08/08 1:39 p.m.•183 views

Hcxdumptool - Small Tool To Capture Packets From Wlan Devices

Small tool to capture packets from wlan devices. After capturing, upload the "uncleaned" cap here https://wpa-sec.stanev.org/?submit to see if your ap or the client is vulnerable by using common wordlists. Convert the cap to hccapx and/or to WPA-PMKID-PBKDF2 hashline 16800 with hcxpcaptool hcxtoo...

7.2AI score
SaveExploits0References1
CNVD
CNVD
•added 2018/08/08 12:00 a.m.•21 views

CloudBees Jenkins Maven Artifact ChoiceListProvider (Nexus) Plugin Information Disclosure Vulnerability

CloudBees Jenkins is the United States CloudBees company's set of Java-based development of continuous integration tools , it is mainly used to monitor the continuous software version of the release/testing project and some of the timed execution of the task . Maven Artifact ChoiceListProvider...

5.4CVSS5.3AI score0.00681EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2018/08/07 12:00 a.m.•11 views

PT-2018-1433

Name of the Vulnerable Software and Affected Versions Medtronic MMT 508 MiniMed insulin pump versions 508 through 751 Medtronic MMT 522 / MMT - 722 Paradigm REAL-TIME Medtronic MMT 523 / MMT - 723 Paradigm Revel Medtronic MMT 523K / MMT - 723K Paradigm Revel Medtronic MMT 551 / MMT - 751 MiniMed...

6.1CVSS0.00712EPSS
SaveExploits0References6
ICS
ICS
•added 2018/08/07 12:00 a.m.•66 views

Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...

5.9AI score
SaveExploits0References5
Rows per page
Query Builder