Lucene search
+L

361 matches found

Prion
Prion
added 2020/03/24 5:15 p.m.22 views

Authentication flaw

In Notifier Web Server NWS Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser...

6.4CVSS9.3AI score0.01325EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/03/24 4:38 p.m.22 views

CVE-2020-6972

In Notifier Web Server NWS Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser...

9.3AI score0.01325EPSS
SaveExploits0References1
CVE
CVE
added 2020/03/24 4:38 p.m.51 views

CVE-2020-6972

CVE-2020-6972 affects Honeywell/NWS Notifier Web Server (NWS-3) versions 3.50 and earlier. The vulnerability is an authentication bypass by a capture-replay attack from a web browser, with CVSS v3.1 base score 9.1 (Network, Privileges None, User Interaction None; Confidentiality/Integrity High, A...

9.1CVSS9.2AI score0.01325EPSS
SaveExploits0References1Affected Software1
ICS
ICS
added 2019/12/12 12:00 a.m.85 views

Omron PLC CJ and CS Series

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Omron Equipment : PLC CJ and CS Series Vulnerabilities : Authentication Bypass by Spoofing, Authentication Bypass by Capture-replay, Unrestricted Externally Accessible Lock 2. UPDATE This updated...

9.8CVSS9.6AI score0.0211EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.34 views

Schneider-electric Modicon Authentication Bypass by Capture-replay

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...

9.8CVSS3.7AI score0.02478EPSS
SaveExploits0References3
Prion
Prion
added 2019/06/11 6:29 p.m.13 views

Authentication flaw

An authentication bypass in website post requests in the Tzumi Electronics Klic Lock application 1.0.9 for mobile devices allows attackers to access resources that are not otherwise accessible without proper authentication via capture-replay. Physically proximate attackers can use this informatio...

4.3CVSS4.4AI score0.01588EPSS
SaveExploits2References2Affected Software2
OSV
OSV
added 2019/06/11 6:29 p.m.7 views

CVE-2019-11334

An authentication bypass in website post requests in the Tzumi Electronics Klic Lock application 1.0.9 for mobile devices allows attackers to access resources that are not otherwise accessible without proper authentication via capture-replay. Physically proximate attackers can use this informatio...

3.7CVSS5.8AI score0.01588EPSS
SaveExploits2References2
CVE
CVE
added 2019/06/11 5:43 p.m.110 views

CVE-2019-11334

The CVE-2019-11334 issue is an authentication bypass in the Tzumi Electronics Klic Lock ecosystem. The vulnerability affects the Klic Lock mobile app (version 1.0.9) and the Klic Smart Padlock (Firmware 6.2). Attackers can exploit capture-replay of website POST requests to access resources that s...

4.3CVSS4.4AI score0.01588EPSS
SaveExploits2References2Affected Software1
Cvelist
Cvelist
added 2019/06/11 5:43 p.m.36 views

CVE-2019-11334

An authentication bypass in website post requests in the Tzumi Electronics Klic Lock application 1.0.9 for mobile devices allows attackers to access resources that are not otherwise accessible without proper authentication via capture-replay. Physically proximate attackers can use this informatio...

4.3AI score0.01588EPSS
SaveExploits2References2
Positive Technologies
Positive Technologies
added 2019/06/11 12:00 a.m.7 views

PT-2019-12246 · Tzumi Electronics · Klic Lock +1

Name of the Vulnerable Software and Affected Versions: Tzumi Electronics Klic Lock application version 1.0.9 Tzumi Electronics Klic Smart Padlock Model 5686 Firmware 6.2 Description: The issue allows attackers to bypass authentication in website post requests, enabling them to access resources th...

4.3CVSS4.3AI score0.01588EPSS
SaveExploits2References3
Prion
Prion
added 2019/04/11 2:29 p.m.22 views

Authentication flaw

Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...

5.4CVSS7.8AI score0.00642EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2019/04/11 2:29 p.m.13 views

CVE-2019-3915

Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...

7.5CVSS7.4AI score0.00642EPSS
SaveExploits0References2
NVD
NVD
added 2019/04/11 2:29 p.m.19 views

CVE-2019-3915

Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...

7.5CVSS7.8AI score0.00642EPSS
SaveExploits0References2
CVE
CVE
added 2019/04/11 1:59 p.m.48 views

CVE-2019-3915

CVE-2019-3915 applies to Verizon Fios Quantum Gateway (G1100) firmware 02.01.00.05. The vulnerability is an authentication bypass via capture‑replay: because the web admin interface relies on HTTP (not HTTPS), an adjacent‑network attacker can intercept login requests and replay them to gain admin...

7.5CVSS7.7AI score0.00642EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2019/04/11 1:59 p.m.29 views

CVE-2019-3915

Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...

7.8AI score0.00642EPSS
SaveExploits0References2
Schneier on Security
Schneier on Security
added 2018/10/29 11:18 a.m.33 views

Security Vulnerability in Internet-Connected Construction Cranes

This seems bad: The F25 software was found to contain a capture replay vulnerability -- basically an attacker would be able to eavesdrop on radio transmissions between the crane and the controller, and then send their own spoofed commands over the air to seize control of the crane. "These devices...

7.2AI score
SaveExploits0
ICS
ICS
added 2018/10/23 12:00 a.m.527 views

Telecrane F25 Series

1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Low skill level to exploit Vendor: Telecrane Equipment: F25 Series Vulnerability: Authentication Bypass by Capture-Replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthorized users to view commands, replay commands,...

8.1CVSS8.3AI score0.00663EPSS
SaveExploits0References5
CVE
CVE
added 2018/08/13 10:00 p.m.71 views

CVE-2018-14781

CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/08/13 10:00 p.m.31 views

CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.3AI score0.00712EPSS
SaveExploits0References3
NVD
NVD
added 2018/08/13 9:48 p.m.25 views

CVE-2018-14781

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3
Rows per page