487 matches found
CVE-2019-3915
Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...
Security Vulnerability in Internet-Connected Construction Cranes
This seems bad: The F25 software was found to contain a capture replay vulnerability -- basically an attacker would be able to eavesdrop on radio transmissions between the crane and the controller, and then send their own spoofed commands over the air to seize control of the crane. "These devices...
Telecrane F25 Series
1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Low skill level to exploit Vendor: Telecrane Equipment: F25 Series Vulnerability: Authentication Bypass by Capture-Replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthorized users to view commands, replay commands,...
CVE-2018-14781
CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...
CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...
CVE-2018-14781
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...
Default configuration
Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options...
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)
1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...
CVE-2018-2402
In systems using the optional capture & replay functionality of SAP HANA, 1.00 and 2.00, see SAP Note 2362820 for more information about capture & replay, user credentials may be stored in clear text in the indexserver trace files of the control system. An attacker with the required authorization...
CVE-2018-2402
SAP HANA vulnerability CVE-2018-2402 affects the optional capture & replay feature in SAP HANA versions 1.00 and 2.00. The root cause is that user credentials can be stored in plaintext in the control system’s indexserver trace files, enabling an attacker with required authorizations on the contr...
CVE-2018-2402
In systems using the optional capture & replay functionality of SAP HANA, 1.00 and 2.00, see SAP Note 2362820 for more information about capture & replay, user credentials may be stored in clear text in the indexserver trace files of the control system. An attacker with the required authorization...
CVE-2017-8865
Elemental Path's CogniToys Dino smart toys through firmware version 0.0.794 do not provide sufficient protections against capture-replay attacks, allowing an attacker on the network to replay VoIP traffic between a Dino device and remote server to any other Dino device...
Path traversal
Elemental Path's CogniToys Dino smart toys through firmware version 0.0.794 do not provide sufficient protections against capture-replay attacks, allowing an attacker on the network to replay VoIP traffic between a Dino device and remote server to any other Dino device...
CVE-2017-8865
Elemental Path's CogniToys Dino smart toys through firmware version 0.0.794 do not provide sufficient protections against capture-replay attacks, allowing an attacker on the network to replay VoIP traffic between a Dino device and remote server to any other Dino device...
CVE-2017-8865
CVE-2017-8865 affects Elemental Path’s CogniToys Dino, with firmware version 0.0.794 and earlier. The vulnerability allows an attacker on the network to replay VoIP traffic between a Dino device and a remote server to another Dino device, indicating a capture-replay flaw in the Dino’s communicati...
CVE-2017-8865
Elemental Path's CogniToys Dino smart toys through firmware version 0.0.794 do not provide sufficient protections against capture-replay attacks, allowing an attacker on the network to replay VoIP traffic between a Dino device and remote server to any other Dino device...
CVE-2017-6034
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6034
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
Authentication flaw
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...