Lucene search
+L

137 matches found

CNNVD
CNNVD
•added 2022/07/13 12:00 a.m.•13 views

Schneider Electric SpaceLogic C-Bus Home Controller 操作系统命令注入漏洞

The Schneider Electric SpaceLogic C-Bus Home Controller is a powerful, fully integrated system from Schneider Electric, France. It can control and automate lighting and many other electrical systems and products. An operating system command injection vulnerability exists in Schneider Electric...

8.8CVSS8AI score0.71284EPSS
SaveExploits6References4
attackerkb
attackerkb
•added 2022/07/12 11:00 a.m.•7 views

CVE-2022-34753

A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller 5200WHC2, formerly known as C-Bus Wiser Homer Controlle...

8.8CVSS6AI score0.71284EPSS
SaveExploits6References4Affected Software1
BDU FSTEC
BDU FSTEC
•added 2022/06/21 12:00 a.m.•17 views

The vulnerabilities of Schneider Electric’s automation controllers with microprogrammed software, such as C-Bus (LSS5500NAC), Wiser for C-Bus (LSS5500SHAC), Clipsal C-Bus (5500NAC), Clipsal Wiser for C-Bus (5500SHAC), and SpaceLogic C-Bus (5500NAC2), SpaceLogic C-Bus (5500AC2), are related to errors during authentication procedures. These vulnerabilities allow attackers to gain full access to the devices.

The vulnerabilities of Schneider Electric’s automation controllers—C-Bus LSS5500NAC, Wiser for C-Bus LSS5500SHAC, Clipsal C-Bus 5500NAC, Clipsal Wiser for C-Bus 5500SHAC, and SpaceLogic C-Bus 5500NAC2, 5500AC2—are related to authentication process errors. Exploiting these vulnerabilities can allo...

10CVSS7.8AI score0.00788EPSS
SaveExploits0References2Affected Software5
BDU FSTEC
BDU FSTEC
•added 2022/06/21 12:00 a.m.•16 views

The vulnerabilities of Schneider Electric’s automation controllers with microprogrammed software, such as C-Bus (LSS5500NAC), Wiser for C-Bus (LSS5500SHAC), Clipsal C-Bus (5500NAC), Clipsal Wiser for C-Bus (5500SHAC), and SpaceLogic C-Bus (5500NAC2), are related to weak password requirements. This allows attackers to gain full access to the devices.

The vulnerabilities of Schneider Electric’s automation controllers with microprogrammed software, such as C-Bus LSS5500NAC, Wiser for C-Bus LSS5500SHAC, Clipsal C-Bus 5500NAC, Clipsal Wiser for C-Bus 5500SHAC, and SpaceLogic C-Bus 5500NAC2, 5500AC2, are related to weak password requirements...

10CVSS7.8AI score0.00695EPSS
SaveExploits0References2Affected Software5
Positive Technologies
Positive Technologies
•added 2022/06/14 12:00 a.m.•14 views

PT-2022-2950 · Spacelogic +1 · Spacelogic C-Bus Application Controller +3

Name of the Vulnerable Software and Affected Versions: C-Bus Network Automation Controller - LSS5500NAC versions prior to V1.10.0 Wiser for C-Bus Automation Controller - LSS5500SHAC versions prior to V1.10.0 Clipsal C-Bus Network Automation Controller - 5500NAC versions prior to V1.10.0 Clipsal...

10CVSS9.6AI score0.00788EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2022/06/14 12:00 a.m.•14 views

PT-2022-2949 · Spacelogic +1 · Spacelogic C-Bus Application Controller +3

Name of the Vulnerable Software and Affected Versions: C-Bus Network Automation Controller - LSS5500NAC versions prior to V1.10.0 Wiser for C-Bus Automation Controller - LSS5500SHAC versions prior to V1.10.0 Clipsal C-Bus Network Automation Controller - 5500NAC versions prior to V1.10.0 Clipsal...

10CVSS9.7AI score0.00695EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
•added 2022/06/06 12:00 a.m.•14 views

The vulnerability of Schneider Electric’s automation controllers C-Bus (5500SHAC) and Wiser for C-Bus (5500SHAC) stems from the possibility of inserting commands that allow a malicious actor to execute arbitrary commands on behalf of the superuser.

The vulnerability of Schneider Electric’s automation controllers C-Bus 5500SHAC and Wiser for C-Bus 5500SHAC lies in the possibility of command injection. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands on behalf of the superuser...

9CVSS6AI score
SaveExploits0References3Affected Software2
Exploit DB
Exploit DB
•added 2022/06/03 12:00 a.m.•317 views

Schneider Electric C-Bus Automation Controller (5500SHAC) 1.10 - Remote Code Execution (RCE)

Exploit Title: Schneider Electric C-Bus Automation Controller 5500SHAC 1.10 - Remote Code Execution RCE Exploit Author: LiquidWorm !/usr/bin/env python3 -- coding: utf-8 -- Schneider Electric C-Bus Automation Controller 5500SHAC 1.10 Remote Root Exploit Vendor: Schneider Electric SE Product web...

5.3AI score
SaveExploits0
zdt
zdt
•added 2022/05/31 12:00 a.m.•235 views

Schneider Electric C-Bus Automation Controller (5500SHAC) 1.10 Remote Root Exploit

Schneider Electric C-Bus Automation Controller 5500SHAC version 1.10 suffers from an authenticated arbitrary command execution vulnerability. An attacker can abuse the Start-up init script editor and exploit the script POST parameter to insert malicious Lua script code and execute commands with...

8.1AI score
SaveExploits0
Packet Storm
Packet Storm
•added 2022/05/30 12:00 a.m.•300 views

Schneider Electric C-Bus Automation Controller (5500SHAC) 1.10 Remote Root

!/usr/bin/env python3 -- coding: utf-8 -- Schneider Electric C-Bus Automation Controller 5500SHAC 1.10 Remote Root Exploit Vendor: Schneider Electric SE Product web page: https://www.se.com | https://www.clipsal.com Product details: -...

0.6AI score
SaveExploits0
Zero Science Lab
Zero Science Lab
•added 2022/05/29 12:00 a.m.•471 views

Schneider Electric C-Bus Automation Controller (5500SHAC) 1.10 Remote Root Exploit

Summary The C-Bus Network Automation Controller 5500NAC and the Wiser for C-Bus Automation Controller 5500SHAC is an advanced controller from Schneider Electric. It is specifically designed to unite the C-Bus home automation solution with common household communication protocols, from lighting an...

6.3AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
•added 2022/04/27 12:00 a.m.•21 views

The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory, allowing a perpetrator to execute arbitrary code.

The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory. Exploiting this vulnerability allows a malicious actor to execute arbitrary code during the file loading process...

9CVSS8AI score0.40582EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
•added 2022/04/27 12:00 a.m.•15 views

The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory, allowing a perpetrator to execute arbitrary code.

The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

9CVSS7.2AI score0.30534EPSS
SaveExploits1References5Affected Software2
NVD
NVD
•added 2022/02/11 6:15 p.m.•29 views

CVE-2021-22796

A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

7.8CVSS0.01197EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2022/02/11 6:15 p.m.•7 views

CVE-2021-22796

A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

7.8CVSS7.7AI score0.01197EPSS
SaveExploits0References2
OSV
OSV
•added 2022/02/11 6:15 p.m.•17 views

CVE-2021-22796

A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

7.8CVSS6.3AI score0.01197EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2022/02/11 6:15 p.m.•6 views

CVE-2021-22748

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

8.8CVSS7.8AI score0.01855EPSS
SaveExploits0References2
OSV
OSV
•added 2022/02/11 6:15 p.m.•17 views

CVE-2021-22748

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

8.8CVSS6.3AI score0.01855EPSS
SaveExploits0References1
NVD
NVD
•added 2022/02/11 6:15 p.m.•32 views

CVE-2021-22748

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

8.8CVSS0.01855EPSS
SaveExploits0References1
Prion
Prion
•added 2022/02/11 6:15 p.m.•22 views

Path traversal

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit V1.15.9 and prior, C-Gate Server V2.11.7 and prior...

6.5CVSS8.9AI score0.01855EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder