Schneider Electric SpaceLogic C-Bus Toolkit
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : SpaceLogic C-Bus Toolkit Vulnerabilities : Improper Privilege Management, Path Traversal 2. RISK EVALUATION Successful exploitation of these vulnerabilities...
The software’s vulnerability in integrating the SpaceLogic system management system with the C-Bus SpaceLogic C-Bus Toolkit allows unauthorized access to files by attackers, due to deficiencies in path name limitation.
The vulnerability of the SpaceLogic system integration software with the C-Bus SpaceLogic C-Bus Toolkit is related to deficiencies in path name limitation. Exploiting this vulnerability can allow an intruder to gain unauthorized access to files...
The software’s vulnerability in integrating the SpaceLogic system management system with the C-Bus SpaceLogic C-Bus Toolkit allows a intruder to execute arbitrary code. This vulnerability arises from the insecure handling of privileges, enabling the intruder to perform unauthorized actions.
The vulnerability of the SpaceLogic system integration software with the C-Bus SpaceLogic C-Bus Toolkit is related to insecure management of privileges. Exploiting this vulnerability allows a malicious actor to execute arbitrary code...
CVE-2023-5399
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command...
CVE-2023-5399
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command...
CVE-2023-5399
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command...
CVE-2023-5399
Schneider Electric C-Bus Toolkit (SpaceLogic C-Bus Toolkit) contains a path traversal flaw in the FileCommand feature that can allow unauthenticated remote code execution. The root cause is improper validation of a user-supplied path prior to file operations, enabling an attacker to tamper with f...
Schneider Electric C-Bus Toolkit Path Traversal Vulnerability
Schneider Electric C-Bus Toolkit is an application from Schneider Electric, France. It is used to run, configure and debug C-Bus installations on a personal computer. The Schneider Electric C-Bus Toolkit is vulnerable to a path traversal vulnerability that stems from the presence of a path...
Schneider Electric SpaceLogic C-Bus Home Controller Security Vulnerability
The Schneider Electric SpaceLogic C-Bus Home Controller is a powerful, fully integrated system from Schneider Electric, France. It can control and automate lighting and many other electrical systems and products. A security vulnerability exists in the Schneider Electric SpaceLogic C-Bus Home...
PT-2023-6039 · Schneider Electric · C-Bus Toolkit
Name of the Vulnerable Software and Affected Versions: Schneider Electric C-Bus Toolkit affected versions not specified Description: A path traversal issue exists due to improper limitation of a pathname to a restricted directory. This could cause tampering of files on the personal computer runni...
The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory, allowing a perpetrator to execute arbitrary code.
The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...
The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory. This allows a perpetrator to execute arbitrary code.
The vulnerability of the C-Bus Toolkit software exists due to an incorrect limitation on the path name to the restricted access directory. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...
CVE-2022-32514
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller - LSS5500SHAC...
CVE-2022-32513
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...
CVE-2022-32513
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...
Authentication flaw
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller - LSS5500SHAC...
Default credentials
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...
Schneider Electric C-Bus多款产品 授权问题漏洞
Schneider Electric C-Bus Home Automation is a series of bus-based home automation systems from French company Schneider Electric. An authorization issue vulnerability exists in various Schneider Electric C-Bus products, which stems from an improper authentication mechanism that allows an attacker...
CVE-2022-32513
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...
CVE-2022-32514
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller - LSS5500SHAC...