297 matches found
Factlink: Proxy service crash DoS
Sending certain URLs to the proxy appears to crash the service, leading to a 502 Bad Gateway from nginx, presumably until the service is restarted. The following sequence sent in a short period appears to cause the crash it could just be the javascript:confirm request, as the last request receive...
CVE-2013-5741
Triangle Research International aka Tri Nano-10 PLC devices with firmware r81 and earlier do not properly handle large length values in MODBUS data, which allows remote attackers to cause a denial of service transition to the interrupt state via a crafted packet to TCP port 502...
Code injection
Triangle Research International aka Tri Nano-10 PLC devices with firmware r81 and earlier do not properly handle large length values in MODBUS data, which allows remote attackers to cause a denial of service transition to the interrupt state via a crafted packet to TCP port 502...
CVE-2013-5741
Triangle Research International aka Tri Nano-10 PLC devices with firmware r81 and earlier do not properly handle large length values in MODBUS data, which allows remote attackers to cause a denial of service transition to the interrupt state via a crafted packet to TCP port 502...
Tri-PLC Nano-10 r81 Denial Of Service
Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's ability to handle a Modbus packet with the bit quanti...
Tri-PLC Nano-10 r81 - Denial of Service
Exploit for hardware platform in category dos / poc Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's...
Tri-PLC Nano-10 r81 - Denial of Service
Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's ability to handle a Modbus packet with the bit quanti...
Tri-PLC Nano-10 r81 - Denial of Service
Tri-PLC Nano-10 r81 - Denial of Service Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's ability to...
CVE-2013-2784
Triangle Research International aka Tri Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service networking outage via a crafted packet to TCP port 502...
Out-of-bounds
Triangle Research International aka Tri Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service networking outage via a crafted packet to TCP port 502...
CVE-2013-2784
Triangle Research International aka Tri Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service networking outage via a crafted packet to TCP port 502...
Adobe Flash Player 11,5,502,135 memory corruption
The vulnerability cause a Memory corruption via a specially crafted Flv files. Successful exploits can allow attackers to execute arbitrary code Title : Adobe Flash Player 11,5,502,135 memory corruption Version : 11,5,502,135 Date : 2012-12-17 Vendor : http://www.adobe.com/ Impact : High Contact ...
Modbus Unit ID and Station ID Enumerator
Modbus is a cleartext protocol used in common SCADA systems, developed originally as a serial-line RS232 async protocol, and later transformed to IP, which is called ModbusTCP. default tcp port is 502. This module sends a command 0x04, read input register to the modbus endpoint. If this command i...
Non-MODBUS Scada Traffic Over Port 502
There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...
CVE-2011-4861
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
Code injection
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
CVE-2011-4861
The CVE-2011-4861 entry concerns Schneider Electric Quantum Ethernet Module (NOE 771 / Quantum 140NOE771*) that allows remote firmware updates via the MODBUS 125 function code sent to TCP port 502 through the modbus_125_handler. This is a software/firmware update mechanism vulnerability in the de...
CVE-2011-4861
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
Apache Reverse Proxy Bypass Vulnerability Scanner
Scan for poorly configured reverse proxy servers. By default, this module attempts to force the server to make a request with an invalid domain name. Then, if the bypass is successful, the server will look it up and of course fail, then responding with a status code 502. A baseline status code is...
Design/Logic Flaw
Microsoft Office 2008 for Mac, when running on Macintosh systems that restrict Office access to administrators, does not enforce this restriction for user ID 502, which allows local users with that ID to bypass intended security policy and access Office programs, related to permissions and...