Modbus Unit ID and Station ID Enumerator

🗓️ 28 Oct 2012 14:11:10Reported by EsMnemon <[email protected]>Type 
metasploit
 metasploit
🔗 www.rapid7.com👁 49 Views

Modbus protocol overview with unit ID and station ID enumeratio

Code
##
# This module requires Metasploit: https://metasploit.com/download
# Current source: https://github.com/rapid7/metasploit-framework
##

class MetasploitModule < Msf::Auxiliary
  include Msf::Exploit::Remote::Tcp
  include Msf::Auxiliary::Fuzzer

  def initialize(info = {})
    super(update_info(info,
      'Name'           => 'Modbus Unit ID and Station ID Enumerator',
      'Description'    => %q{
        Modbus is a cleartext protocol used in common SCADA systems, developed
        originally as a serial-line (RS232) async protocol, and later transformed
        to IP, which is called ModbusTCP. default tcp port is 502.

        This module sends a command (0x04, read input register) to the modbus endpoint.
        If this command is sent to the correct unit-id, it returns with the same function-id.
        if not, it should be added 0x80, so that it sys 0x84, and an exception-code follows
        which do not interest us. This does not always happen, but at least the first 4
        bytes in the return-packet should be exact the same as what was sent.

        You can change port, ip and the scan-range for unit-id. There is also added a
        value - BENICE - to make the scanner sleep a second or more between probes. We
        have seen installations where scanning too many too fast works like a DoS.
      },
      'References'  =>
        [
          [ 'URL', 'https://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx' ],
          [ 'URL', 'https://en.wikipedia.org/wiki/Modbus:TCP' ]
        ],
      'Author'         => [ 'EsMnemon <esm[at]mnemonic.no>' ],
      'License'        => MSF_LICENSE,
      'DisclosureDate' => '2012-10-28'
    ))

    register_options(
      [
        Opt::RPORT(502),
        OptInt.new('UNIT_ID_FROM', [true, "ModBus Unit Identifier scan from value [1..254]", 1]),
        OptInt.new('UNIT_ID_TO', [true, "ModBus Unit Identifier scan to value [UNIT_ID_FROM..254]", 254]),
        OptInt.new('BENICE', [true, "Seconds to sleep between StationID-probes, just for being nice", 1]),
        OptInt.new('TIMEOUT', [true, 'Timeout for the network probe, 0 means no timeout', 2])
      ])
  end

  def run
    start="\x21\x00\x00\x00\x00\x06"
    theend="\x04\x00\x01\x00\x00"
    noll="\x00"
    # between, \01..\0ff  (1-255)
    unless (1..255).include? datastore['UNIT_ID_FROM']
      print_status("unit ID must be between 1 and 254 adjusting  UNIT_ID_FROM to 1")
      datastore['UNIT_ID_FROM']=1
    end

    unless (1..255).include? datastore['UNIT_ID_TO']
      print_status("Unit ID must be between #{datastore['UNIT_ID_FROM']} and 255")
      print_warning("Adjusting UNIT_ID_TO to #{datastore['UNIT_ID_FROM']} ")
      datastore['UNIT_ID_TO'] = datastore['UNIT_ID_FROM']
    end

    if datastore['UNIT_ID_FROM'] > datastore['UNIT_ID_TO'] then
      print_warning("UNIT_ID_TO is less than UNIT_ID_FROM, setting them equal")
      datastore['UNIT_ID_TO'] = datastore['UNIT_ID_FROM']
    end

    datastore['UNIT_ID_FROM'].upto(datastore['UNIT_ID_TO']) do |counter|
      sploit  = start
      sploit += [counter].pack("C")
      sploit += theend
      select(nil,nil,nil,datastore['BENICE'])
      connect()
      sock.put(sploit)

      data = sock.get_once(12, datastore['TIMEOUT'])
      if (data.nil?)
        data=noll+noll+noll+noll
      end

      if data[0,4]  == "\x21\x00\x00\x00"  #return of the same trans-id+proto-id
        print_good("Received: correct MODBUS/TCP from stationID  #{counter}")
      else
        print_status("Received: incorrect/none data from stationID #{counter} (probably not in use)")
      end

      disconnect()
    end
  end
end


=begin
For testing purposes:

  This client is developed and tested against a SAIA PCD1.M2 system
  https://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx
  and a modbus/tcp PLC simulator from plcsimulator.org
  and the Modbus SLAVE from http://www.modbustools.com/

  Mission is to find Unit-ID/stationID of the modbus-endpoint:
  RHOST=IP of the modbus-service (PLC)
  RPORT=Usually 502
=end

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation