560 matches found
SUSE CVE-2013-1080
The web server in Novell ZENworks Configuration Management ZCM 10.3 and 11.2 before 11.2.4 does not properly perform authentication for zenworks/jsp/index.jsp, which allows remote attackers to conduct directory traversal attacks, and consequently upload and execute arbitrary programs, via a reque...
CVE-2022-40717
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected D-Link DIR-2150 4.0.1 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the anweb service, which listens on TCP ports 80 and 443 by default. The issue...
CVE-2022-40717
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected D-Link DIR-2150 4.0.1 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the anweb service, which listens on TCP ports 80 and 443 by default. The issue...
Stack overflow
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected D-Link DIR-2150 4.0.1 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the anweb service, which listens on TCP ports 80 and 443 by default. The issue...
CVE-2022-40718
CVE-2022-40718 concerns D-Link DIR-2150 (firmware 4.0.1). The flaw is a stack-based buffer overflow in the anweb service (listening on TCP ports 80/443) caused by improper validation of user-supplied data length, allowing network-adjacent attackers to execute code with root privileges. Multiple s...
Siemens SCALANCE X Products Missing Authentication For Critical Function (CVE-2020-15799)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...
Siemens SCALANCE X Switches (CVE-2018-13807)
A vulnerability has been identified in SCALANCE X300 All versions V4.0.0, SCALANCE X408 All versions V4.0.0, SCALANCE X414 All versions. The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The...
Cisco Issues Warning for Unpatched Vulnerabilities in EoL Business Routers
Cisco has warned of two security vulnerabilities affecting end-of-life EoL Small Business RV016, RV042, RV042G, and RV082 routers that it said will not be fixed, even as it acknowledged the public availability of proof-of-concept PoC exploit. The issues are rooted in the router's web-based...
CVE-2022-31698
The vCenter Server contains a denial-of-service vulnerability in the content library service. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to trigger a denial-of-service condition by sending a specially crafted header...
Denial of service
The vCenter Server contains a denial-of-service vulnerability in the content library service. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to trigger a denial-of-service condition by sending a specially crafted header...
CVE-2022-31698
The CVE-2022-31698 entry concerns VMware vCenter Server (and related ESXi components) with a denial-of-service in the content library service. According to the provided documents, a remote attacker who can access port 443 over the network can trigger a DoS by sending a specially crafted header, l...
CVE-2022-31698
The vCenter Server contains a denial-of-service vulnerability in the content library service. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to trigger a denial-of-service condition by sending a specially crafted header...
Siemens多款产品 资源管理错误漏洞
SIPROTEC 5 devices offer a range of integrated protection, control, measurement and automation functions for substations and other applications. A denial of service vulnerability exists in Siemens SIPROTEC 5 Devices, which can be exploited by an attacker to cause a denial of service on ports...
Siemens SIPROTEC 5 Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Vulnerabilities fixed in VMware vCenter and ESXi
VMWare has fixed several vulnerabilities in vCenter Server and ESXi. A malicious party could exploit the vulnerabilities to cause a denial-of-service, to gain access to sensitive data, including cleat-text passwords and, under certain circumstances to break out of the sandbox of a guest environme...
PT-2022-5908 · Vmware · Vmware Vcenter Server +1
Name of the Vulnerable Software and Affected Versions: VMware vCenter Server affected versions not specified Description: The issue is related to a denial-of-service condition in the content library service of VMware vCenter Server. It can be triggered by a malicious actor with network access to...
CVE-2022-43546
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
CVE-2022-43546
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Code injection
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
CVE-2022-43545
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...