D-Link DIR-3040 prog.cgi SetTriggerPPPoEValidate Stack-Based Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 routers. Authentication is required to exploit this vulnerability. The specific flaw exists within the prog.cgi binary, which handles HNAP requests made to the lighttpd...
How to get Odata to work on Https or on port 443 after binding a certificate.
When trying to fetch the Odata API on 443 and it is getting error : HTTP 404 Page not found. Or If the address using which the Odata API is fetched is in HTTP and unable to change it to HTTPS after binding the certificate...
Delta Electronics InfraSuite Device Master APRunning Improper Access Control Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Electronics InfraSuite Device Master. Authentication is required to exploit this vulnerability. The specific flaw exists within the gateway endpoint, which listens on TCP ports 80 and 4...
Exploit for Path Traversal in Icinga Icinga_Web_2
Icinga Web 2 - Authenticated Remote Code Execution 2.8.6, 2.9...
Error "Couldn't connect to server 'https://gwfqdn:non-443' when log on to non-443 port vpn vserver
You may get the following error message"Couldn't connect to server 'https://gwfqdn:non-443'; while attempting to log on to non-443 port NetScaler Gateway virtual server using the latest Windows Secure Access Client. :...
Third Flaw Uncovered in MOVEit Transfer App Amidst Cl0p Ransomware Mass Attack
Progress Software on Thursday disclosed a third vulnerability impacting its MOVEit Transfer application, as the Cl0p cybercrime gang deployed extortion tactics against affected companies. The new flaw, which is being tracked as CVE-2023-35708, also concerns an SQL injection vulnerability that...
Siemens SIMATIC NET CP Modules Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2021-33737)
A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 343-1 ERPC All versions, SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP...
Siemens SIMATIC NET CP 443-1 OPC UA Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2017-6458)
Multiple buffer overflows in the ctlput functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. ...
Siemens SICAM Q100 Improper Input Validation (CVE-2022-43439)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Siemens SICAM Q100 Improper Input Validation (CVE-2022-43545)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Command injection
A vulnerability has been identified in CP-8031 MASTER MODULE All versions CPCI85 V05, CP-8050 MASTER MODULE All versions CPCI85 V05. Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by...
CVE-2023-28489
A vulnerability has been identified in CP-8031 MASTER MODULE All versions CPCI85 V05, CP-8050 MASTER MODULE All versions CPCI85 V05. Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by...
PT-2023-9400 · Siemens · Siplus S7-1200 Cp 1243-1 +20
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 1242-7 V2 versions prior to V3.4.29 SIMATIC CP 1243-1 versions prior to V3.4.29 SIMATIC CP 1243-1 DNP3 versions prior to V3.4.29 SIMATIC CP 1243-1 IEC versions prior to V3.4.29 SIMATIC CP 1243-7 LTE EU versions prior to V3.4.29...
PT-2023-9402 · Siemens · Siplus S7-1200 Cp 1243-1 +20
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 1242-7 V2 versions prior to V3.4.29 SIMATIC CP 1243-1 versions prior to V3.4.29 SIMATIC CP 1243-1 DNP3 versions prior to V3.4.29 SIMATIC CP 1243-1 IEC versions prior to V3.4.29 SIMATIC CP 1243-7 LTE EU versions prior to V3.4.29...
Siemens SCALANCE M875 Cross-site Scripting (CVE-2018-11448)
A vulnerability has been identified in SCALANCE M875 All versions. The web interface on port 443/tcp could allow a stored Cross-Site Scripting XSS attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13926)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold r...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13925)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. This plug...
Input validation
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
EcoStruxure Geo SCADA Expert 安全漏洞
EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable Supervisory Control and Data Acquisition SCADA software. A security vulnerability exists in EcoStruxure Geo SCADA Expert that stems from an improper output neutralization issue with the device's logs, which can lead to incorrec...
CVE-2023-0595