Lucene search
+L

4135 matches found

Tenable Nessus
Tenable Nessus
added 2019/04/01 12:00 a.m.12 views

openSUSE Security Update : ucode-intel (openSUSE-2019-1084)

This update for ucode-intel fixes the following issues : Updated to the 20190312 bundle release bsc1129231 New Platforms : - AML-Y22 H0 6-8e-9/10 0000009e Core Gen8 Mobile - WHL-U W0 6-8e-b/d0 000000a4 Core Gen8 Mobile - WHL-U V0 6-8e-d/94 000000b2 Core Gen8 Mobile - CFL-S P0 6-9e-c/22 000000a2...

5.5AI score
SaveExploits0References1
NVD
NVD
added 2019/03/29 5:29 a.m.38 views

CVE-2019-10269

BWA aka Burrow-Wheeler Aligner before 2019-01-23 has a stack-based buffer overflow in the bnsrestore function in bntseq.c via a long sequence name in a .alt file...

10CVSS9.6AI score0.0291EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2019/03/26 12:00 a.m.19 views

SUSE SLED12 / SLES12 Security Update : ucode-intel (SUSE-SU-2019:0736-1)

This update for ucode-intel fixes the following issues : Updated to the 20190312 bundle release bsc1129231 New Platforms : AML-Y22 H0 6-8e-9/10 0000009e Core Gen8 Mobile WHL-U W0 6-8e-b/d0 000000a4 Core Gen8 Mobile WHL-U V0 6-8e-d/94 000000b2 Core Gen8 Mobile CFL-S P0 6-9e-c/22 000000a2 Core Gen9...

5.5AI score
SaveExploits0References2
Prion
Prion
added 2019/03/25 7:29 p.m.18 views

Design/Logic Flaw

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

5CVSS6.8AI score0.00771EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/03/25 6:20 p.m.25 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5AI score0.00771EPSS
SaveExploits0References1
CVE
CVE
added 2019/03/25 6:20 p.m.52 views

CVE-2015-1012

The CVE-2015-1012 entry concerns the Hospira LifeCare PCA Infusion System. Vulnerabilities include cleartext storage of wireless network keys and hardcoded credentials, with multiple related issues (e.g., improper authorization, insufficient verification of data authenticity) that could enable un...

7.5CVSS7.5AI score0.00771EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2019/03/25 5:29 p.m.17 views

Design/Logic Flaw

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira...

10CVSS7.3AI score0.02036EPSS
SaveExploits0References1Affected Software3
Prion
Prion
added 2019/03/25 5:29 p.m.22 views

Hardcoded credentials

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS6.9AI score0.01972EPSS
SaveExploits0References1Affected Software3
NVD
NVD
added 2019/03/25 5:29 p.m.25 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS9.5AI score0.01972EPSS
SaveExploits0References1
NVD
NVD
added 2019/03/25 5:29 p.m.20 views

CVE-2015-3954

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira...

10CVSS9.7AI score0.02036EPSS
SaveExploits0References1
NVD
NVD
added 2019/03/25 4:29 p.m.28 views

CVE-2015-3952

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

7.5CVSS8AI score0.01008EPSS
SaveExploits0References1
Prion
Prion
added 2019/03/25 4:29 p.m.23 views

Authorization

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

5CVSS6.6AI score0.01008EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
added 2019/03/25 4:12 p.m.29 views

CVE-2015-3954

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira...

9.7AI score0.02036EPSS
SaveExploits0References1
CVE
CVE
added 2019/03/25 4:12 p.m.62 views

CVE-2015-3954

Hospira Plum A+ Infusion System (versions 13.4 and earlier), Plum A+3 Infusion System (13.6 and earlier), and Symbiq Infusion System (3.13 and earlier) expose unauthenticated root privileges on Port 23/TELNET by default, allowing an unauthorized user to issue pump commands. Hospira notes Plum 360...

10CVSS9.5AI score0.02036EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/03/25 4:02 p.m.26 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

9.5AI score0.01972EPSS
SaveExploits0References1
CVE
CVE
added 2019/03/25 4:02 p.m.51 views

CVE-2015-3953

CVE-2015-3953 affects Hospira Plum A+ Infusion System (versions prior to 13.4), Plum A+3 Infusion System (prior to 13.6), and Symbiq Infusion System (prior to 3.13). Root cause: hard-coded credentials allowing access via affected devices; additional risk factors include services listening on Port...

10CVSS9.2AI score0.01972EPSS
SaveExploits0References1Affected Software1
Tenable Nessus
Tenable Nessus
added 2019/03/25 12:00 a.m.12 views

SUSE SLED15 / SLES15 Security Update : ucode-intel (SUSE-SU-2019:0712-1)

This update for ucode-intel fixes the following issues : Updated to the 20190312 bundle release bsc1129231 New Platforms : AML-Y22 H0 6-8e-9/10 0000009e Core Gen8 Mobile WHL-U W0 6-8e-b/d0 000000a4 Core Gen8 Mobile WHL-U V0 6-8e-d/94 000000b2 Core Gen8 Mobile CFL-S P0 6-9e-c/22 000000a2 Core Gen9...

5.5AI score
SaveExploits0References2
Kitploit
Kitploit
added 2019/03/22 8:22 p.m.233 views

SMS-Stack - Framework to provided TPC/IP based characteristics to the GSM Short Message Service

Sms Stack is a Framework to provided TPC/IP based characteristics to the GSM Short Message Service. This framework works in multiple environments to provided a full stack integration in a service. The main layer features techniques to control the order and the number of sms for a given stream, an...

7.2AI score
SaveExploits0References1
Prion
Prion
added 2019/03/21 4:29 p.m.16 views

Sql injection

RISI Gestao de Horarios v3201.09.08 rev.23 allows SQL Injection...

6.5CVSS8.9AI score0.01246EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2019/03/21 3:36 p.m.36 views

CVE-2019-6491

CVE-2019-6491 affects RISI Gestao de Horarios v3201.09.08 rev.23 and is a SQL injection vulnerability. CVSSv3 base score 8.8 (HIGH): NETWORK, LOW attack complexity, PRIVs LOW, no user interaction; impacts Confidentiality, Integrity, Availability (HIGH). CVSSv2 base 6.5 (MEDIUM). No remediation de...

8.8CVSS8.8AI score0.01246EPSS
SaveExploits1References1Affected Software1
Rows per page
Query Builder