1667 matches found
Siemens SIMATIC S7-1500 Cleartext Transmission of Sensitive Information (CVE-2023-23914)
A cleartext transmission of sensitive information vulnerability exists in curl v7.88.0 that could cause HSTS functionality fail when multiple URLs are requested serially. Using its HSTS support, curl can be instructed to use HTTPS instead of usingan insecure clear-text HTTP step even when HTTP is...
Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2020-10531)
An issue was discovered in International Components for Unicode ICU for C/C++ through 66.1. An integer overflow, leading to a heap-based buffer overflow, exists in the UnicodeString::doAppend function in common/unistr.cpp. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 Improper Neutralization of CRLF Sequences (CVE-2019-9947)
An issue was discovered in urllib2 in Python 2.x through 2.7.16 and urllib in Python 3.x through 3.7.3. CRLF injection is possible if the attacker controls a url parameter, as demonstrated by the first argument to urllib.request.urlopen with \r\n specifically in the path component of a URL that...
Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2023-34319)
The fix for XSA-423 added logic to Linux'es netback driver to deal with a frontend splitting a packet in a way such that not all of the headers would come in one piece. Unfortunately the logic introduced there didn't account for the extreme case of the entire packet being split into as many piece...
Siemens SIMATIC S7-1500 Improper Handling of Exceptional Conditions (CVE-2019-20218)
selectExpander in select.c in SQLite 3.30.1 proceeds with WITH stack unwinding even after a parsing error. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2023-34969)
D-Bus before 1.15.6 sometimes allows unprivileged users to crash dbus- daemon. If a privileged user with control over the dbus-daemon is using the org.freedesktop.DBus.Monitoring interface to monitor message bus traffic, then an unprivileged user with the ability to connect to the same dbus-daemo...
Siemens RUGGEDCOM and SCALANCE Type Confusion (CVE-2024-49860)
CPI: sysfs: validate return type of STR method Only buffer objects are valid return values of STR. If something else is returned descriptionshow will access invalid memory. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2025-21787)
team: better TEAMOPTIONTYPESTRING validation This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503529; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-38635)
soundwire: cadence: invalid PDI offset. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503406; scriptversion"1.2";...
Siemens SIMATIC Devices Out-of-bounds Write (CVE-2024-35966)
Bluetooth: RFCOMM: Fix not validating setsockopt user input This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503668; scriptversion"1.2";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Missing Initialization of a Variable (CVE-2024-53101)
In the Linux kernel, the following vulnerability has been resolved: fs: Fix uninitialized value issue in fromkuid and fromkgid ocfs2setattr uses attr-iamode, attr-iauid and attr-iagid in a trace point even though ATTRMODE, ATTRUID and ATTRGID aren't set. Initialize all fields of newattrs to avoid...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-38579)
crypto: bcm - Fix pointer arithmetic In spu2dumpomd value of ptr is increased by ciphkeylen instead of hashivlen which could lead to going beyond the buffer boundaries. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Write (CVE-2024-50008)
wifi: mwifiex: memcpy field-spanning write warning in mwifiexcmd80211scanext Replace one-element array with a flexible-array member in struct hostcmdds80211scanext. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-38547)
media: atomisp: sshcss: null-pointer dereference in loadvideobinaries. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503608; scriptversion"1.2";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40995)
net/sched: actapi: possible infinite loop in tcfidrcheckalloc. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503394; scriptversion"1.3";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Control of a Resource Through its Lifetime (CVE-2024-47713)
wifi: mac80211: vulnerability caused by implementing a two-phase skb reclamation in ieee80211dostop to avoid warnings and potential issues caused by calling devqueuexmit with interrupts disabled. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-39509)
HID: core: remove unnecessary WARNON in implement. There is a warning in a call to implement when trying to write a value into a field of smaller size in an output report. Since implement already has a warn message printed out with the help of hidwarn and value in question gets trimmed with:...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2025-21862)
dropmonitor: incorrect initialization order. If dropmonitor is built as a kernel module, syzkaller may have time to send a netlink NETDMCMDSTART message during the module loading. This will call the netdmmonitorstart function that uses a spinlock that has not yet been initialized. This plugin onl...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Write (CVE-2024-49973)
r8169: RTL8125 added fields to the tally counter, this change could cause the chip to perform Direct Memory Access on these new fields, potentially writing to unallocated memory. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SIMATIC Devices NULL Pointer Dereference (CVE-2024-42276)
In the Linux kernel, the following vulnerability has been resolved: nvme-pci: add missing condition check for existence of mapped data nvmemapdata is called when request has physical segments, hence the nvmeunmapdata should have same condition to avoid dereference. This plugin only works with...