Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Missing Initialization of a Variable (CVE-2024-53101)
| Reporter | Title | Published | Views | Family All 229 |
|---|---|---|---|---|
| Astra Linux – Vulnerability in Linux 6.1 | 11 Feb 202507:35 | – | astralinux | |
| The vulnerability of the fs component in the Linux operating system’s kernel allows a hacker to trigger a service failure. | 14 Apr 202500:00 | – | bdu_fstec | |
| CVE-2024-53101 | 25 Nov 202421:46 | – | circl | |
| Linux kernel 安全漏洞 | 25 Nov 202400:00 | – | cnnvd | |
| CVE-2024-53101 | 25 Nov 202421:21 | – | cve | |
| CVE-2024-53101 fs: Fix uninitialized value issue in from_kuid and from_kgid | 25 Nov 202421:21 | – | cvelist | |
| [SECURITY] [DLA 4008-1] linux-6.1 security update | 3 Jan 202500:41 | – | debian | |
| [SECURITY] [DLA 4075-1] linux security update | 1 Mar 202521:07 | – | debian | |
| CVE-2024-53101 | 25 Nov 202421:21 | – | debiancve | |
| Debian dla-4008 : linux-config-6.1 - security update | 3 Jan 202500:00 | – | nessus |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503638);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");
script_cve_id("CVE-2024-53101");
script_xref(name:"ICSA", value:"25-226-07");
script_name(english:"Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Missing Initialization of a Variable (CVE-2024-53101)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
fs: Fix uninitialized value issue in from_kuid and from_kgid
ocfs2_setattr() uses attr->ia_mode, attr->ia_uid and attr->ia_gid in a
trace point even though ATTR_MODE, ATTR_UID and ATTR_GID aren't set.
Initialize all fields of newattrs to avoid uninitialized variables, by
checking if ATTR_MODE, ATTR_UID, ATTR_GID are initialized, otherwise
0.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-265688.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-53101");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(456);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"patch_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1", "versionStartIncluding" : "1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]},
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xcm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xch-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrh-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
12 Feb 2026 00:00Current
6.2Medium risk
Vulners AI Score6.2
CVSS 3.15.5
EPSS0.00248
SSVC