Lucene search
+L

596 matches found

CNVD
CNVD
added 2022/02/08 12:00 a.m.101 views

Multiple Siemens Industrial Products Denial of Service Vulnerabilities

SIMATIC Drive Controller family products are machines designed for production automation, combining the functionality of the SIMATIC S7-1500 CPU and the SINAMICS S120 drive control.SIMATIC S7-1200 CPU family products are designed for discrete and continuous control in industrial environments such...

7.5CVSS7.5AI score0.0206EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.40 views

Siemens S7-1200 and S7-200 SMART CPUs Exposed Dangerous Method or Function (CVE-2019-13945)

A vulnerability has been identified in SIMATIC S7-1200 CPU family incl. SIPLUS variants All versions, SIMATIC S7-1200 CPU family V4.x incl. SIPLUS variants All versions, SIMATIC S7-1200 CPU family V4.x incl. SIPLUS variants All versions with Function State FS 11, SIMATIC S7-200 SMART CPU CR20s 6E...

6.8CVSS6.4AI score0.00532EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2256)

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257. This plugin only works with Tenable.ot. Please visit...

7.8CVSS5.5AI score0.03609EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.31 views

Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2018-13815)

A vulnerability has been identified in SIMATIC S7-1200 All versions, SIMATIC S7-1500 All Versions V2.6. An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be abl...

7.5CVSS7AI score0.01799EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.15 views

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2252)

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. This plugin only works with Tenable.ot. Please visit...

6.1CVSS5.5AI score0.01253EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Siemens SIMATIC S7-1500 & S7-1200 Cross-Site Request Forgery (CVE-2014-2249)

Cross-site request forgery CSRF vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. This plugin only works...

5.8CVSS5.5AI score0.01344EPSS
SaveExploits1References7
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.30 views

Siemens SIMATIC Improper Certificate Validation (CVE-2012-3037)

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate. This plugin only works with Tenable.ot. Plea...

4.3CVSS7.2AI score0.01472EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.61 views

Siemens SIMATIC Products Use of a Broken or Risky Cryptographic Algorithm (CVE-2019-10929)

Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices. This plugin only work...

5.9CVSS6AI score0.00978EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.25 views

Siemens SIMATIC S7-1200 Open Redirect (CVE-2015-1048)

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. This plugin only works with Tenable.ot. Please visit...

4.3CVSS5.8AI score0.01493EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.41 views

Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-2780)

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to UDP port 161 aka the SNMP port. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

7.8CVSS5.5AI score0.02392EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.62 views

Siemens SIMATIC S7-1200 and S7-1500 CPU Families Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2020-15782)

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...

9.8CVSS8.5AI score0.05184EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-0700)

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to TCP port 102 aka the ISO-TSAP port. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...

7.8CVSS5.5AI score0.02392EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.62 views

Siemens SIMATIC S7-1200 and S7-1500 CPU Families Missing Support For Integrity Check (CVE-2019-10943)

An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the...

7.5CVSS7.2AI score0.00952EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.43 views

Siemens SIMATIC S7-1200 Cross-Site Request Forgery (CVE-2015-5698)

Cross-site request forgery CSRF vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. This plugin only works with Tenable.ot. Please visit...

7.5CVSS5.5AI score0.03339EPSS
SaveExploits2References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.28 views

Siemens SIMATIC S7-1200 Improper Privilege Management (CVE-2016-2846)

Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a user program block protection mechanism via unspecified vectors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable...

6.5CVSS6.6AI score0.01691EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Siemens SIMATIC S7-1200 Improper Authentication (CVE-2021-37172)

A vulnerability has been identified in SIMATIC S7-1200 CPU family incl. SIPLUS variants V4.5.0. Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication an...

7.5CVSS7AI score0.00922EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.32 views

Siemens SIMATIC S7-1200 HTTP Response Splitting (CVE-2014-2909)

CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

5.8CVSS5.8AI score0.02417EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.25 views

Siemens SIMATIC S7-1200 HTTP Response Splitting (CVE-2014-2908)

Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...

4.3CVSS5.7AI score0.20862EPSS
SaveExploits3References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.28 views

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2254)

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255. This plugin only works with Tenable.ot. Please visit...

7.8CVSS5.5AI score0.04642EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Siemens SIMATIC Cross-site Scripting (CVE-2012-3040)

Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

4.3CVSS7.3AI score0.02556EPSS
SaveExploits1References6
Rows per page
Query Builder