Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2014-2254.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2254)

2022-02-0700:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
9

7.8 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

6.7 Medium

AI Score

Confidence

Low

0.008 Low

EPSS

Percentile

81.5%

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets, a different vulnerability than CVE-2014-2255.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500112);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/12/26");

  script_cve_id("CVE-2014-2254");

  script_name(english:"Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2254)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service
(defect-mode transition) via crafted HTTP packets, a different vulnerability than CVE-2014-2255.  

This plugin only
works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?919f964f");
  script_set_attribute(attribute:"see_also", value:"http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2014-2254");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(399);

  script_set_attribute(attribute:"vuln_publication_date", value:"2014/03/24");
  script_set_attribute(attribute:"patch_publication_date", value:"2014/03/24");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7_cpu_1200_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7_cpu_1200_firmware:3.0");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7_cpu_1200_firmware" :
        {"versionEndIncluding" : "3.0.2", "family" : "S71200"},
    "cpe:/o:siemens:simatic_s7_cpu_1200_firmware:3.0" :
        {"versionEndIncluding" : "3.0", "versionStartIncluding" : "3.0", "family" : "S71200"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemenssimatic_s7_cpu_1200_firmwarecpe:/o:siemens:simatic_s7_cpu_1200_firmware
siemenssimatic_s7_cpu_1200_firmware3.0cpe:/o:siemens:simatic_s7_cpu_1200_firmware:3.0

7.8 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

6.7 Medium

AI Score

Confidence

Low

0.008 Low

EPSS

Percentile

81.5%

Related for TENABLE_OT_SIEMENS_CVE-2014-2254.NASL