320 matches found
Siemens EN100 Ethernet Module Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2022-30937)
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
Upgraded Q -> H from 104 [1656255316696]
Judge has assessed an item in Issue 104 as High risk. The relevant finding follows: L02: Incompatibility with ERC-4626 Line References Description The EIP-4626 specification requires that totalAssets to NOT revert, but the current implementation does so in the underlying methods: int256...
CVE-2022-30937
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
CVE-2022-30937
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
Memory corruption
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
CVE-2022-30937
CVE-2022-30937 affects Siemens EN100 Ethernet Module variants: DNP3 IP, IEC 104, IEC 61850 (all versions prior to 4.37), Modbus TCP, and PROFINET IO. The issue is a memory corruption vulnerability in the HTTP parsing of the /txtrace endpoint, which could crash the affected application and cause a...
Siemens EN100 Ethernet Module
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: EN100 Ethernet Module Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could...
Upgraded Q -> M from 104 [1654442859269]
Judge has assessed an item in Issue 104 as Medium risk. The relevant finding follows: Check transfer receiver is not 0 to avoid burned money Transferring tokens to the zero address is usually prohibited to accidentally avoid "burning" tokens by sending them to an unrecoverable zero address. Code...
CVE-2021-46052
A Denial of Service vulnerability exists in Binaryen 104 due to an assertion abort in wasm::Tuple::validate...
PT-2022-5036 · Hitachi Energy · Hitachi Energy Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: Hitachi Energy MicroSCADA Pro SYS600 versions 9.0 through 9.4 FP2 Hotfix 4 Hitachi Energy MicroSCADA X SYS600 versions 10 through 10.3.1 Description: The issue is caused by improper input validation in the handling of a malformed IEC 104 TCP...
CVE-2022-1039 ICSA-22-104-03 Red Lion DA50N
The weak password on the web user interface can be exploited via HTTP or HTTPS. Once such access has been obtained, the other passwords can be changed. The weak password on Linux accounts can be accessed via SSH or Telnet, the former of which is by default enabled on trusted interfaces. While the...
Siemens PROFINET Stack Integrated on Interniche Stack
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SIPROTEC Information Disclosure (CVE-2016-4784)
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens EN100 Ethernet module & SIPROTEC Merging Unit Denial of Service (CVE-2015-5374)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
lib60870代码问题漏洞
lib60870 is a C language library based on the IEC60870-5 protocol. The library provides support for CompanionStandard 101 CS101 and 104 CS104 of the IEC family of standards for remote control applications IEC60870-5 and is commonly used in power systems for communication between central station...
CVE-2021-46054
A Denial of Service vulnerability exists in Binaryen 104 due to an assertion abort in wasm::WasmBinaryBuilder::visitRethrowwasm::Rethrow...
DEBIAN-CVE-2021-46054
A Denial of Service vulnerability exists in Binaryen 104 due to an assertion abort in wasm::WasmBinaryBuilder::visitRethrowwasm::Rethrow...