Lucene search
+L

12035 matches found

Kitploit
Kitploit
•added 2026/10/18 11:38 a.m.•100 views

fluffi

FLUFFI FLUFFI - A distributed evolutionary binary fuzzer for pentesters. About the project High level overview Beginner Tutorial Getting started Usage HOWTOs Technical Details Contributing to FLUFFI LICENSE Bugs found So far, FLUFFI was almost exclusively used on SIEMENS products and solutions...

5.3CVSS7.1AI score0.04116EPSS
SaveExploits0References9
Kitploit
Kitploit
•added 2026/10/18 3:27 a.m.•21 views

CVE-2015-5374-DoS-PoC

CVE-2015-5374 Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module CVE-2015-5374 Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module ... Done, say goodbye! Metasploit Module This module sends a specially crafted packet to Port 50000/UDP could cause a denial of service of the...

7.8CVSS7.7AI score0.74497EPSS
SaveExploits7
Kitploit
Kitploit
•added 2026/10/17 4:59 p.m.•25 views

ICSSecurityScripts

ICSSecurityScripts Industrial Security Scripts Beckhoff-CX9020-WebControl.py: Controlling the Beckhoff CX9020 Windows CE PLC FullBeckhoffScan.py: Elaborate script for scanning AND hacking Beckhoff PLCs PhoenixControlPLC-ILC150.py: Print out CPU status and reverts it, tested and working on ILC150 ...

6.1AI score
SaveExploits0
Nuclei
Nuclei
•added 2026/10/17 2:05 a.m.•60 views

SINEMA Remote Connect Server < V2.0 - Open Redirect

A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0. Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks. id: CVE-2022-23102...

6.1CVSS5.9AI score0.04718EPSS
SaveExploits2References5
Nuclei
Nuclei
•added 2026/10/16 2:05 a.m.•97 views

Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting

A cross-site scripting vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. id: CVE-2014-2908 info: name: Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting author:...

4.3CVSS5.8AI score0.20862EPSS
SaveExploits4References5
Kitploit
Kitploit
•added 2026/10/16 12:11 a.m.•19 views

APOLOGEE

🌀 APOLOGEE - Siemens Field Panel Scanner: APOLOGEE is a Python script and Metasploit module that enumerates a hidden directory on Siemens APOGEE PXC BACnet Automation Controllers all versions prior to V3.5 and TALON TC BACnet Automation Controllers all versions prior to V3.5. With a 7.5 CVSS, thi...

5.3CVSS6.6AI score0.07344EPSS
SaveExploits4References1
Kitploit
Kitploit
•added 2026/10/15 6:51 p.m.•24 views

CVE-2026-41551

CVE-2026-41551 Reproduction Vulnerability: Siemens ROS fileserver / fileserver2 service relative path traversal CVSS v3.1: 9.1 AV:N / AC:L / PR:N / UI:N / S:U / C:H / I:H / A:N Affected versions: ros-sharp all name.substr10; // remove "package://" std::string package = address.substr0,...

9.3CVSS8.2AI score0.0064EPSS
SaveExploits0
NVD
NVD
•added 2026/10/15 3:17 p.m.•8 views

CVE-2026-110936

A vulnerability has been identified in Siemens Software Center All versions V4.0.9.8. The affected application loads dynamic-link libraries DLLs from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application...

8.4CVSS0.00135EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/10/15 2:01 p.m.•6 views

CVE-2026-110936

A vulnerability has been identified in Siemens Software Center All versions V4.0.9.8. The affected application loads dynamic-link libraries DLLs from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application...

8.4CVSS6.3AI score0.00135EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/10/15 2:01 p.m.•8 views

EUVD-2026-102072

A vulnerability has been identified in Siemens Software Center All versions. The affected application loads dynamic-link libraries DLLs from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches,...

8.4CVSS6.4AI score0.00135EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/10/15 2:01 p.m.•41 views

CVE-2026-110936

A vulnerability has been identified in Siemens Software Center All versions V4.0.9.8. The affected application loads dynamic-link libraries DLLs from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application...

8.4CVSS0.00135EPSS
SaveExploits0References1
CVE
CVE
•added 2026/10/15 2:01 p.m.•21 views

CVE-2026-110936

A vulnerability exists in Siemens Software Center (all versions) because the application loads dynamic-link libraries (DLLs) from an uncontrolled search path . This flaw allows an authenticated local attacker to place a specially crafted DLL in a searched directory, potentially leading to arbitra...

8.4CVSS6.3AI score0.00135EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2026/10/15 12:00 a.m.•7 views

PT-2026-114947

Name of the Vulnerable Software and Affected Versions Siemens Software Center affected versions not specified Description The application loads dynamic-link libraries DLLs from an uncontrolled search path. This allows an authenticated local attacker to place a specially crafted DLL in a directory...

8.4CVSS6.4AI score0.00135EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/10/15 12:00 a.m.•3 views

CVE-2026-110936: Uncontrolled Search Path Element

A vulnerability has been identified in Siemens Software Center All versions V4.0.9.8. The affected application loads dynamic-link libraries DLLs from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application...

8.4CVSS6.3AI score0.00135EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/10/13 12:00 a.m.•11 views

PT-2026-111380

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC Drive Controller CPU 1504D TF affected versions not specified Description Devices do not properly restrict executable content within imported trace files. An attacker could social engineer an authorized user with the "Read...

9.6CVSS6AI score0.00413EPSS
SaveExploits0References10
Kitploit
Kitploit
•added 2026/10/12 9:22 p.m.•21 views

Stuxnet

Stuxnet This repository contains a strictly educational and research-oriented reconstruction of the infamous Stuxnet worm. It is the product of countless hours of reverse engineering work conducted by the global security research community on the original binary samples discovered in 2010. Warnin...

6.3AI score
SaveExploits0
Kitploit
Kitploit
•added 2026/10/11 2:35 p.m.•22 views

fluffi

FLUFFI FLUFFI - Un fuzzer binario evolutivo distribuido para pentesters. Acerca del proyecto Visión general de alto nivel Tutorial para principiantes Primeros pasos Uso HOWTOs Detalles técnicos Contribuir a FLUFFI LICENCIA Bugs encontrados Hasta ahora, FLUFFI se ha utilizado casi exclusivamente e...

5.3CVSS7.3AI score0.04116EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
•added 2026/10/02 12:00 a.m.•18 views

Siemens SIMATIC S7-1500 CPU 1518 MFP Improper Input Validation (CVE-2026-46303)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid505960; scriptversion"1.2"; scriptsetattributeattribute:"pluginmodificationdate",...

8.2CVSS7.7AI score0.00564EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2026/10/02 12:00 a.m.•19 views

Siemens SIMATIC S7-1500 CPU 1518 MFP Improper Input Validation (CVE-2026-46086)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid505970; scriptversion"1.2"; scriptsetattributeattribute:"pluginmodificationdate",...

5.5CVSS5.5AI score0.00129EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2026/10/02 12:00 a.m.•18 views

Siemens SIMATIC S7-1500 CPU 1518 MFP Expired Pointer Dereference (CVE-2026-53006)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid506017; scriptversion"1.2"; scriptsetattributeattribute:"pluginmodificationdate",...

9.8CVSS6AI score0.00394EPSS
SaveExploits0References2
Rows per page