| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| CVE-2026-25786 | 12 May 202608:20 | – | attackerkb | |
| CVE-2026-25786 | 12 May 202611:32 | – | circl | |
| Siemens多款产品 跨站脚本漏洞 | 12 May 202600:00 | – | cnnvd | |
| CVE-2026-25786 | 12 May 202608:20 | – | cve | |
| CVE-2026-25786 | 12 May 202608:20 | – | cvelist | |
| EUVD-2026-29426 | 12 May 202612:32 | – | euvd | |
| Vulnerabilities present in Siemens products | 13 May 202606:33 | – | ncsc | |
| CVE-2026-25786 | 12 May 202610:16 | – | nvd | |
| PT-2026-39984 | 12 May 202600:00 | – | ptsecurity | |
| CVE-2026-25786 | 5 Jun 202619:23 | – | redhatcve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505539);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/15");
script_cve_id("CVE-2026-25786");
script_xref(name:"ICSA", value:"26-134-15");
script_name(english:"Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25786)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Affected devices do not properly validate and sanitize PLC/station
name rendered on the 'communication' parameters page of the web
interface. This could allow an authenticated attacker who is
authorized to download a TIA project into the product, to inject
malicious scripts into the page. If a benign user with appropriate
rights accesses the 'communication' parameters page, the malicious
code would be executed in the scope of their web session.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-688146.html");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-15");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H");
script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-25786");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(79);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/05/12");
script_set_attribute(attribute:"patch_publication_date", value:"2026/05/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/06");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et200sp_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et200pro_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:all" :
{"family" : "S71500", "orderNumbers" : ['6ES7511-1AK00-0AB0', '6ES7511-1AL03-0AB0', '6ES7511-1CL03-0AB0', '6ES7511-1FK00-0AB0', '6ES7511-1FL03-0AB0', '6ES7511-1TL03-0AB0', '6ES7511-1UL03-0AB0', '6ES7512-1CM03-0AB0', '6ES7513-1AL00-0AB0', '6ES7513-1AM03-0AB0', '6ES7513-1FL00-0AB0', '6ES7513-1FM03-0AB0', '6ES7513-2GM03-0AB0', '6ES7513-2PM03-0AB0', '6ES7515-2AM00-0AB0', '6ES7515-2AN03-0AB0', '6ES7515-2FM00-0AB0', '6ES7515-2FN03-0AB0', '6ES7515-2TN03-0AB0', '6ES7515-2UN03-0AB0', '6ES7516-2GP03-0AB0', '6ES7516-2PP03-0AB0', '6ES7516-3AN00-0AB0', '6ES7516-3AP03-0AB0', '6ES7516-3FN00-0AB0', '6ES7516-3FP03-0AB0', '6ES7516-3TP10-0AB0', '6ES7516-3UP10-0AB0', '6ES7517-3AQ10-0AB0', '6ES7517-3FQ10-0AB0', '6ES7517-3TQ10-0AB0', '6ES7517-3UQ10-0AB0', '6ES7518-3AT10-0AB0', '6ES7518-3FT10-0AB0', '6ES7518-3TT10-0AB0', '6ES7518-3UT10-0AB0', '6ES7518-4AP00-3AB0', '6ES7518-4FP00-3AB0']},
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:2.9.9" :
{"versionEndExcluding" : "2.9.9", "family" : "S71500", "orderNumbers" : ['6ES7511-1AK01-0AB0', '6ES7511-1AK02-0AB0', '6ES7511-1CK00-0AB0', '6ES7511-1CK01-0AB0', '6ES7511-1FK01-0AB0', '6ES7511-1FK02-0AB0', '6ES7511-1TK01-0AB0', '6ES7511-1UK01-0AB0', '6ES7512-1CK00-0AB0', '6ES7512-1CK01-0AB0', '6ES7513-1AL01-0AB0', '6ES7513-1AL02-0AB0', '6ES7513-1FL01-0AB0', '6ES7513-1FL02-0AB0', '6ES7515-2AM01-0AB0', '6ES7515-2AM02-0AB0', '6ES7515-2FM01-0AB0', '6ES7515-2FM02-0AB0', '6ES7515-2TM01-0AB0', '6ES7515-2UM01-0AB0', '6ES7516-3AN01-0AB0', '6ES7516-3AN02-0AB0', '6ES7516-3FN01-0AB0', '6ES7516-3FN02-0AB0']},
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.6" :
{"versionEndExcluding" : "3.1.6", "family" : "S71500", "orderNumbers" : ['6ES7516-3TN00-0AB0', '6ES7516-3UN00-0AB0', '6ES7517-3AP00-0AB0', '6ES7517-3FP00-0AB0', '6ES7517-3FP01-0AB0', '6ES7517-3TP00-0AB0', '6ES7517-3UP00-0AB0', '6ES7518-4AP00-0AB0', '6ES7518-4AX00-1AB0', '6ES7518-4AX00-1AC0', '6ES7518-4FP00-0AB0', '6ES7518-4FX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4TP00-0AB0', '6ES7518-4UP00-0AB0', '6ES7615-4DF10-0AB0', '6ES7615-7DF10-0AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:all" :
{"family" : "S71500", "orderNumbers" : ['6AG1511-1AK00-2AB0', '6AG1511-1FK00-2AB0', '6AG1513-1AL00-2AB0', '6AG1513-1FL00-2AB0', '6AG1516-3AN00-2AB0', '6AG1516-3AN00-7AB0', '6AG1516-3FN00-2AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:2.9.9" :
{"versionEndExcluding" : "2.9.9", "family" : "S71500", "orderNumbers" : ['6AG1511-1AK01-2AB0', '6AG1511-1AK01-7AB0', '6AG1511-1AK02-2AB0', '6AG1511-1AK02-7AB0', '6AG1511-1FK01-2AB0', '6AG1511-1FK02-2AB0', '6AG1513-1AL01-2AB0', '6AG1513-1AL01-7AB0', '6AG1513-1AL02-2AB0', '6AG1513-1AL02-7AB0', '6AG1513-1FL01-2AB0', '6AG1513-1FL02-2AB0', '6AG1515-2FM01-2AB0', '6AG1515-2FM02-2AB0', '6AG1516-3AN01-2AB0', '6AG1516-3AN01-7AB0', '6AG1516-3AN02-2AB0', '6AG1516-3AN02-7AB0', '6AG1516-3FN01-2AB0', '6AG1516-3FN02-2AB0', '6AG2511-1AK01-1AB0', '6AG2511-1AK01-4AB0', '6AG2511-1AK02-1AB0', '6AG2511-1AK02-4AB0', '6AG2515-2FM01-2AB0', '6AG2515-2FM02-4AB0', '6AG2516-3AN01-4AB0', '6AG2516-3AN02-4AB0', '6AG2516-3FN02-2AB0', '6AG2516-3FN02-4AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.6" :
{"versionEndExcluding" : "3.1.6", "family" : "S71500", "orderNumbers" : ['6AG1518-4AP00-4AB0', '6AG1518-4AX00-4AC0', '6AG1518-4FP00-4AB0']},
"cpe:/o:siemens:simatic_et200sp_firmware:all" :
{"family" : "ET200SP", "orderNumbers" : ['6AG1512-1SK00-2AB0', '6ES7510-1DJ00-0AB0', '6ES7510-1DK03-0AB0', '6ES7510-1SJ00-0AB0', '6ES7510-1SK03-0AB0', '6ES7512-1DK00-0AB0', '6ES7512-1DM03-0AB0', '6ES7512-1SK00-0AB0', '6ES7512-1SM03-0AB0', '6ES7514-2DN03-0AB0', '6ES7514-2SN03-0AB0', '6ES7514-2VN03-0AB0', '6ES7514-2WN03-0AB0']},
"cpe:/o:siemens:simatic_et200sp_firmware:2.9.9" :
{"versionEndExcluding" : "2.9.9", "family" : "ET200SP", "orderNumbers" : ['6AG1510-1DJ01-2AB0', '6AG1510-1DJ01-7AB0', '6AG1510-1SJ01-2AB0', '6AG1512-1DK01-2AB0', '6AG1512-1DK01-7AB0', '6AG1512-1SK01-2AB0', '6AG1512-1SK01-7AB0', '6AG2510-1DJ01-1AB0', '6AG2510-1DJ01-4AB0', '6AG2510-1SJ01-1AB0', '6AG2512-1DK01-1AB0', '6AG2512-1DK01-4AB0', '6AG2512-1SK01-1AB0', '6AG2512-1SK01-4AB0', '6ES7510-1DJ01-0AB0', '6ES7510-1SJ01-0AB0', '6ES7512-1DK01-0AB0', '6ES7512-1SK01-0AB0']},
"cpe:/o:siemens:simatic_et200pro_firmware:2.9.9" :
{"versionEndExcluding" : "2.9.9", "family" : "ET200", "orderNumbers" : ['6ES7513-2GL00-0AB0', '6ES7513-2PL00-0AB0', '6ES7516-2GN00-0AB0', '6ES7516-2PN00-0AB0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation