Lucene search
+L

Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25786)

🗓️ 06 Jul 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 7 Views

Siemens S7-1500 XSS via communication page enables script injection by authenticated users.

Related
Refs
Code
ReporterTitlePublishedViews
Family
ATTACKERKB
CVE-2026-25786
12 May 202608:20
attackerkb
Circl
CVE-2026-25786
12 May 202611:32
circl
CNNVD
Siemens多款产品 跨站脚本漏洞
12 May 202600:00
cnnvd
CVE
CVE-2026-25786
12 May 202608:20
cve
Cvelist
CVE-2026-25786
12 May 202608:20
cvelist
EUVD
EUVD-2026-29426
12 May 202612:32
euvd
NCSC
Vulnerabilities present in Siemens products
13 May 202606:33
ncsc
NVD
CVE-2026-25786
12 May 202610:16
nvd
Positive Technologies
PT-2026-39984
12 May 202600:00
ptsecurity
RedhatCVE
CVE-2026-25786
5 Jun 202619:23
redhatcve
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(505539);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/15");

  script_cve_id("CVE-2026-25786");
  script_xref(name:"ICSA", value:"26-134-15");

  script_name(english:"Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25786)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Affected devices do not properly validate and sanitize PLC/station
name rendered on the 'communication' parameters page of the web
interface. This could allow an authenticated attacker who is
authorized to download a TIA project into the product, to inject
malicious scripts into the page. If a benign user with appropriate
rights accesses the 'communication' parameters page, the malicious
code would be executed in the scope of their web session.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-688146.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-15");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-25786");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/05/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/05/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/06");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et200sp_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et200pro_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:all" :
        {"family" : "S71500", "orderNumbers" : ['6ES7511-1AK00-0AB0', '6ES7511-1AL03-0AB0', '6ES7511-1CL03-0AB0', '6ES7511-1FK00-0AB0', '6ES7511-1FL03-0AB0', '6ES7511-1TL03-0AB0', '6ES7511-1UL03-0AB0', '6ES7512-1CM03-0AB0', '6ES7513-1AL00-0AB0', '6ES7513-1AM03-0AB0', '6ES7513-1FL00-0AB0', '6ES7513-1FM03-0AB0', '6ES7513-2GM03-0AB0', '6ES7513-2PM03-0AB0', '6ES7515-2AM00-0AB0', '6ES7515-2AN03-0AB0', '6ES7515-2FM00-0AB0', '6ES7515-2FN03-0AB0', '6ES7515-2TN03-0AB0', '6ES7515-2UN03-0AB0', '6ES7516-2GP03-0AB0', '6ES7516-2PP03-0AB0', '6ES7516-3AN00-0AB0', '6ES7516-3AP03-0AB0', '6ES7516-3FN00-0AB0', '6ES7516-3FP03-0AB0', '6ES7516-3TP10-0AB0', '6ES7516-3UP10-0AB0', '6ES7517-3AQ10-0AB0', '6ES7517-3FQ10-0AB0', '6ES7517-3TQ10-0AB0', '6ES7517-3UQ10-0AB0', '6ES7518-3AT10-0AB0', '6ES7518-3FT10-0AB0', '6ES7518-3TT10-0AB0', '6ES7518-3UT10-0AB0', '6ES7518-4AP00-3AB0', '6ES7518-4FP00-3AB0']},
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:2.9.9" :
        {"versionEndExcluding" : "2.9.9", "family" : "S71500", "orderNumbers" : ['6ES7511-1AK01-0AB0', '6ES7511-1AK02-0AB0', '6ES7511-1CK00-0AB0', '6ES7511-1CK01-0AB0', '6ES7511-1FK01-0AB0', '6ES7511-1FK02-0AB0', '6ES7511-1TK01-0AB0', '6ES7511-1UK01-0AB0', '6ES7512-1CK00-0AB0', '6ES7512-1CK01-0AB0', '6ES7513-1AL01-0AB0', '6ES7513-1AL02-0AB0', '6ES7513-1FL01-0AB0', '6ES7513-1FL02-0AB0', '6ES7515-2AM01-0AB0', '6ES7515-2AM02-0AB0', '6ES7515-2FM01-0AB0', '6ES7515-2FM02-0AB0', '6ES7515-2TM01-0AB0', '6ES7515-2UM01-0AB0', '6ES7516-3AN01-0AB0', '6ES7516-3AN02-0AB0', '6ES7516-3FN01-0AB0', '6ES7516-3FN02-0AB0']},
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.6" :
        {"versionEndExcluding" : "3.1.6", "family" : "S71500", "orderNumbers" : ['6ES7516-3TN00-0AB0', '6ES7516-3UN00-0AB0', '6ES7517-3AP00-0AB0', '6ES7517-3FP00-0AB0', '6ES7517-3FP01-0AB0', '6ES7517-3TP00-0AB0', '6ES7517-3UP00-0AB0', '6ES7518-4AP00-0AB0', '6ES7518-4AX00-1AB0', '6ES7518-4AX00-1AC0', '6ES7518-4FP00-0AB0', '6ES7518-4FX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4TP00-0AB0', '6ES7518-4UP00-0AB0', '6ES7615-4DF10-0AB0', '6ES7615-7DF10-0AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:all" :
        {"family" : "S71500", "orderNumbers" : ['6AG1511-1AK00-2AB0', '6AG1511-1FK00-2AB0', '6AG1513-1AL00-2AB0', '6AG1513-1FL00-2AB0', '6AG1516-3AN00-2AB0', '6AG1516-3AN00-7AB0', '6AG1516-3FN00-2AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:2.9.9" :
        {"versionEndExcluding" : "2.9.9", "family" : "S71500", "orderNumbers" : ['6AG1511-1AK01-2AB0', '6AG1511-1AK01-7AB0', '6AG1511-1AK02-2AB0', '6AG1511-1AK02-7AB0', '6AG1511-1FK01-2AB0', '6AG1511-1FK02-2AB0', '6AG1513-1AL01-2AB0', '6AG1513-1AL01-7AB0', '6AG1513-1AL02-2AB0', '6AG1513-1AL02-7AB0', '6AG1513-1FL01-2AB0', '6AG1513-1FL02-2AB0', '6AG1515-2FM01-2AB0', '6AG1515-2FM02-2AB0', '6AG1516-3AN01-2AB0', '6AG1516-3AN01-7AB0', '6AG1516-3AN02-2AB0', '6AG1516-3AN02-7AB0', '6AG1516-3FN01-2AB0', '6AG1516-3FN02-2AB0', '6AG2511-1AK01-1AB0', '6AG2511-1AK01-4AB0', '6AG2511-1AK02-1AB0', '6AG2511-1AK02-4AB0', '6AG2515-2FM01-2AB0', '6AG2515-2FM02-4AB0', '6AG2516-3AN01-4AB0', '6AG2516-3AN02-4AB0', '6AG2516-3FN02-2AB0', '6AG2516-3FN02-4AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.6" :
        {"versionEndExcluding" : "3.1.6", "family" : "S71500", "orderNumbers" : ['6AG1518-4AP00-4AB0', '6AG1518-4AX00-4AC0', '6AG1518-4FP00-4AB0']},
    "cpe:/o:siemens:simatic_et200sp_firmware:all" :
        {"family" : "ET200SP", "orderNumbers" : ['6AG1512-1SK00-2AB0', '6ES7510-1DJ00-0AB0', '6ES7510-1DK03-0AB0', '6ES7510-1SJ00-0AB0', '6ES7510-1SK03-0AB0', '6ES7512-1DK00-0AB0', '6ES7512-1DM03-0AB0', '6ES7512-1SK00-0AB0', '6ES7512-1SM03-0AB0', '6ES7514-2DN03-0AB0', '6ES7514-2SN03-0AB0', '6ES7514-2VN03-0AB0', '6ES7514-2WN03-0AB0']},
    "cpe:/o:siemens:simatic_et200sp_firmware:2.9.9" :
        {"versionEndExcluding" : "2.9.9", "family" : "ET200SP", "orderNumbers" : ['6AG1510-1DJ01-2AB0', '6AG1510-1DJ01-7AB0', '6AG1510-1SJ01-2AB0', '6AG1512-1DK01-2AB0', '6AG1512-1DK01-7AB0', '6AG1512-1SK01-2AB0', '6AG1512-1SK01-7AB0', '6AG2510-1DJ01-1AB0', '6AG2510-1DJ01-4AB0', '6AG2510-1SJ01-1AB0', '6AG2512-1DK01-1AB0', '6AG2512-1DK01-4AB0', '6AG2512-1SK01-1AB0', '6AG2512-1SK01-4AB0', '6ES7510-1DJ01-0AB0', '6ES7510-1SJ01-0AB0', '6ES7512-1DK01-0AB0', '6ES7512-1SK01-0AB0']},
    "cpe:/o:siemens:simatic_et200pro_firmware:2.9.9" :
        {"versionEndExcluding" : "2.9.9", "family" : "ET200", "orderNumbers" : ['6ES7513-2GL00-0AB0', '6ES7513-2PL00-0AB0', '6ES7516-2GN00-0AB0', '6ES7516-2PN00-0AB0']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

15 Jul 2026 00:00Current
7High risk
Vulners AI Score7
CVSS 3.19.1
CVSS 49.3
EPSS0.0037
SSVC
7