Lucene search
+L

Siemens SIPROTEC 5 Allocation of Resources Without Limits or Throttling (CVE-2025-40570)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 5 Views

Siemens SIPROTEC 5 USB bandwidth flaw exhausts memory from packets; devices reset automatically.

Related
Refs
Code
ReporterTitlePublishedViews
Family
circl
Circl
CVE-2025-40570
14 Aug 202510:00
circl
cnnvd
CNNVD
Siemens多款产品 安全漏洞
12 Aug 202500:00
cnnvd
cve
CVE
CVE-2025-40570
12 Aug 202511:17
cve
cvelist
Cvelist
CVE-2025-40570
12 Aug 202511:17
cvelist
euvd
EUVD
EUVD-2025-24247
3 Oct 202520:07
euvd
ics
ICS
Siemens SIPROTEC 5
12 Aug 202500:00
ics
ncsc
NCSC
Vulnerabilities fixed in Siemens products
12 Aug 202513:03
ncsc
nvd
NVD
CVE-2025-40570
12 Aug 202512:15
nvd
ptsecurity
Positive Technologies
PT-2025-32650 · Siemens · Siprotec 5 7Sa82 +16
12 Aug 202500:00
ptsecurity
redhatcve
RedhatCVE
CVE-2025-40570
9 Jan 202610:58
redhatcve
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504808);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/12");

  script_cve_id("CVE-2025-40570");
  script_xref(name:"ICSA", value:"25-226-10");

  script_name(english:"Siemens SIPROTEC 5 Allocation of Resources Without Limits or Throttling (CVE-2025-40570)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Affected devices do not properly limit the bandwidth for incoming
network packets over their local USB port. This could allow an
attacker with physical access to send specially crafted packets with
high bandwidth to the affected devices thus forcing them to exhaust
their memory and stop responding to any network traffic via the local
USB port. Affected devices reset themselves automatically after a
successful attack. The protection function is not affected of this
vulnerability.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-894058.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-10");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109757433/");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109796884/");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814150/");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5
6MU85 (CP300), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD86 (CP300),
SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL86
(CP300), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300),
SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87
(CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300): Update to V10.0 or later version
- SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5
7SK82 (CP150), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UT82 (CP150):
Update to V10.0 or later version
- SIPROTEC 5 Compact 7SX800 (CP050): Update to V10.0 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-894058 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40570");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(770);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware" :
        {"versionEndExcluding" : "10.0", "family" : "Siprotec5"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_NOTE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

12 Mar 2026 00:00Current
5.8Medium risk
Vulners AI Score5.8
CVSS 42.4
CVSS 3.12.4
EPSS0.00197
SSVC
5