Siemens SIPROTEC 5 Allocation of Resources Without Limits or Throttling (CVE-2025-40570)
| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| CVE-2025-40570 | 14 Aug 202510:00 | – | circl | |
| Siemens多款产品 安全漏洞 | 12 Aug 202500:00 | – | cnnvd | |
| CVE-2025-40570 | 12 Aug 202511:17 | – | cve | |
| CVE-2025-40570 | 12 Aug 202511:17 | – | cvelist | |
| EUVD-2025-24247 | 3 Oct 202520:07 | – | euvd | |
| Siemens SIPROTEC 5 | 12 Aug 202500:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 12 Aug 202513:03 | – | ncsc | |
| CVE-2025-40570 | 12 Aug 202512:15 | – | nvd | |
| PT-2025-32650 · Siemens · Siprotec 5 7Sa82 +16 | 12 Aug 202500:00 | – | ptsecurity | |
| CVE-2025-40570 | 9 Jan 202610:58 | – | redhatcve |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504808);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/12");
script_cve_id("CVE-2025-40570");
script_xref(name:"ICSA", value:"25-226-10");
script_name(english:"Siemens SIPROTEC 5 Allocation of Resources Without Limits or Throttling (CVE-2025-40570)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Affected devices do not properly limit the bandwidth for incoming
network packets over their local USB port. This could allow an
attacker with physical access to send specially crafted packets with
high bandwidth to the affected devices thus forcing them to exhaust
their memory and stop responding to any network traffic via the local
USB port. Affected devices reset themselves automatically after a
successful attack. The protection function is not affected of this
vulnerability.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-894058.html");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-10");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109757433/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109796884/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814150/");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5
6MU85 (CP300), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD86 (CP300),
SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL86
(CP300), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300),
SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87
(CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300): Update to V10.0 or later version
- SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5
7SK82 (CP150), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UT82 (CP150):
Update to V10.0 or later version
- SIPROTEC 5 Compact 7SX800 (CP050): Update to V10.0 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
For more information see the associated Siemens security advisory SSA-894058 in HTML and CSAF.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:N/I:N/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N");
script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40570");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(770);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware" :
{"versionEndExcluding" : "10.0", "family" : "Siprotec5"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_NOTE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
12 Mar 2026 00:00Current
5.8Medium risk
Vulners AI Score5.8
CVSS 42.4
CVSS 3.12.4
EPSS0.00197
SSVC