| Reporter | Title | Published | Views | Family All 13 |
|---|---|---|---|---|
| CVE-2024-54017 | 12 May 202608:20 | – | attackerkb | |
| The vulnerability of SIPROTEC 5 devices’ relay protection, automation, and control functions lies in the limited number of possible random values. This allows attackers to gain unauthorized access to the protected information. | 2 Jul 202600:00 | – | bdu_fstec | |
| CVE-2024-54017 | 14 May 202610:00 | – | circl | |
| Siemens SIPROTEC 5 安全漏洞 | 12 May 202600:00 | – | cnnvd | |
| CVE-2024-54017 | 12 May 202608:20 | – | cve | |
| CVE-2024-54017 | 12 May 202608:20 | – | cvelist | |
| EUVD-2024-55574 | 12 May 202612:32 | – | euvd | |
| Siemens SIPROTEC 5 | 12 May 202600:00 | – | ics | |
| Vulnerabilities present in Siemens products | 13 May 202606:33 | – | ncsc | |
| CVE-2024-54017 | 12 May 202610:16 | – | nvd |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505477);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/06/21");
script_cve_id("CVE-2024-54017");
script_name(english:"Siemens SIPROTEC 5 Small Space of Random Values (CVE-2024-54017)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Affected devices do not use sufficiently random values to create
session identifiers. This could allow an unauthenticated remote
attacker to brute force a session identifier and gain read access to
limited information from the web server without authorization.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-786884.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109757433/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109796884/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814150/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-13");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-54017");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(334);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/05/12");
script_set_attribute(attribute:"patch_publication_date", value:"2026/05/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/06/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_cp300_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_cp150_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_cp100_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_cp050_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:siprotec_5_cp300_firmware" :
{"versionEndExcluding" : "11", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_cp150_firmware" :
{"versionEndExcluding" : "11", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_cp100_firmware" :
{"versionStartIncluding" : "7.80", "family" : "Siprotec5"},
"cpe:/o:siemens:siprotec_5_cp050_firmware" :
{"versionEndExcluding" : "11", "family" : "Siprotec5"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation