| Reporter | Title | Published | Views | Family All 288 |
|---|---|---|---|---|
| Astra Linux – Vulnerability in Linux 6.1 | 11 Feb 202507:35 | – | astralinux | |
| The vulnerabilities of the functions dbAdjTree() and dbFindLeaf() in the kernel module fs/jfs/jfs_dmap.c of the Linux operating system allow a hacker to cause a service failure. | 24 Mar 202500:00 | – | bdu_fstec | |
| CVE-2024-49902 affecting package kernel for versions less than 5.15.173.1-1 | 11 Dec 202407:24 | – | cbl_mariner | |
| CVE-2024-49902 | 14 Aug 202510:00 | – | circl | |
| Linux kernel 安全漏洞 | 21 Oct 202400:00 | – | cnnvd | |
| CVE-2024-49902 | 21 Oct 202418:01 | – | cve | |
| CVE-2024-49902 jfs: check if leafidx greater than num leaves per dmap tree | 21 Oct 202418:01 | – | cvelist | |
| [SECURITY] [DLA 4008-1] linux-6.1 security update | 3 Jan 202500:41 | – | debian | |
| [SECURITY] [DLA 4075-1] linux security update | 1 Mar 202521:07 | – | debian | |
| CVE-2024-49902 | 21 Oct 202418:01 | – | debiancve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503436);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");
script_cve_id("CVE-2024-49902");
script_xref(name:"ICSA", value:"25-226-07");
script_name(english:"Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Read (CVE-2024-49902)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"jfs: vulnerability caused by assigning msm_gpu->pdev earlier in the
initialization process to prevent null pointer dereferences in
msm_gpu_cleanup.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-265688.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-49902");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(125);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"patch_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1", "versionStartIncluding" : "1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]},
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xcm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xch-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrh-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation