Siemens SIMATIC S7-1500 and S7-1200 CPUs URL Redirection to Untrusted Site (CVE-2024-46886)
| Reporter | Title | Published | Views | Family All 12 |
|---|---|---|---|---|
| The vulnerability of the web server of the microprogramming software for programmable logic controllers SIMATICS7-1500 and S7-1200 CPU family allows a hacker to redirect users to any desired URL address. | 7 Nov 202400:00 | – | bdu_fstec | |
| CVE-2024-46886 | 8 Oct 202412:02 | – | circl | |
| Siemens SIMATIC S7-1200和Siemens SIMATIC S7-1500 安全漏洞 | 8 Oct 202400:00 | – | cnnvd | |
| Siemens Multiple Products URL Redirection Vulnerability | 10 Oct 202400:00 | – | cnvd | |
| CVE-2024-46886 | 8 Oct 202408:40 | – | cve | |
| CVE-2024-46886 | 8 Oct 202408:40 | – | cvelist | |
| EUVD-2024-42133 | 3 Oct 202520:07 | – | euvd | |
| Siemens SIMATIC S7-1500 and S7-1200 CPUs | 8 Oct 202400:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 8 Oct 202413:49 | – | ncsc | |
| CVE-2024-46886 | 8 Oct 202409:15 | – | nvd |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502651);
script_version("1.5");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/30");
script_cve_id("CVE-2024-46886");
script_xref(name:"ICSA", value:"24-284-01");
script_name(english:"Siemens SIMATIC S7-1500 and S7-1200 CPUs URL Redirection to Untrusted Site (CVE-2024-46886)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The web server of affected devices does not properly validate input
that is used for a user redirection. This could allow an attacker to
make the server redirect the legitimate user to an attacker-chosen
URL. For a successful exploit, the legitimate user must actively click
on an attacker-crafted link.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-876787.html");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-01");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has released new versions for several affected products and recommends users update to the latest versions.
Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or
not yet available:
- SIMATIC Drive Controller CPU: Update to V3.1.4 or later version
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Do not click on links from unknown sources.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-876787 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-46886");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(601);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/10/08");
script_set_attribute(attribute:"patch_publication_date", value:"2024/10/08");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/10/22");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_drive_controller_cpu_firmware:3.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_et_200pro_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1200_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.4");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2024-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware" :
{"family" : "ET200SP"},
"cpe:/o:siemens:simatic_s7-1200_cpu_firmware" :
{"versionEndExcluding" : "4.7.0", "family" : "S71200", "orderNumbers" : ['6ES7211-1AE40-0XB0', '6ES7214-1AG40-0XB0', '6ES7212-1HE40-0XB0', '6ES7215-1HF40-0XB0', '6ES7214-1HF40-0XB0', '6ES7215-1AG40-0XB0', '6ES7214-1BG40-0XB0', '6ES7211-1BE40-0XB0', '6ES7217-1AG40-0XB0', '6ES7212-1AE40-0XB0', '6ES7214-1AF40-0XB0', '6ES7212-1AF40-0XB0', '6ES7212-1HF40-0XB0', '6ES7211-1HE40-0XB0', '6ES7212-1BE40-0XB0', '6ES7215-1HG40-0XB0', '6ES7215-1AF40-0XB0', '6ES7214-1HG40-0XB0', '6ES7215-1BG40-0XB0']},
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware" :
{"family" : "S71500", "orderNumbers" : ['6ES7513-1FL01-0AB0', '6ES7515-2FM02-0AB0', '6ES7516-3AN02-0AB0', '6ES7510-1DJ01-0AB0', '6ES7512-1DK01-0AB0', '6ES7515-2UM01-0AB0', '6ES7511-1TK01-0AB0', '6ES7511-1AK02-0AB0', '6ES7516-3FN02-0AB0', '6ES7515-2AM01-0AB0', '6ES7510-1SJ01-0AB0', '6ES7516-3AN01-0AB0', '6ES7515-2TM01-0AB0', '6ES7511-1UK01-0AB0', '6ES7512-1SK01-0AB0', '6ES7516-3FN01-0AB0', '6ES7511-1FK02-0AB0', '6ES7515-2FM01-0AB0', '6ES7518-4AP00-3AB0', '6ES7511-1AK01-0AB0', '6ES7512-1CK01-0AB0', '6ES7515-2AM02-0AB0', '6ES7511-1FK01-0AB0', '6ES7518-4FP00-3AB0', '6ES7513-1AL02-0AB0', '6ES7511-1CK01-0AB0', '6ES7513-1AL01-0AB0', '6ES7512-1CK00-0AB0', '6ES7513-1FL02-0AB0', '6ES7511-1CK00-0AB0']},
"cpe:/o:siemens:simatic_s7-1500_et_200pro_cpu_firmware" :
{"family" : "ET200", "orderNumbers" : ['6ES7513-2GL00-0AB0', '6ES7516-2GN00-0AB0', '6ES7516-2PN00-0AB0', '6ES7513-2PL00-0AB0']},
"cpe:/o:siemens:siplus_et_200sp_cpu_firmware" :
{"family" : "ET200", "orderNumbers" : ['6AG1510-1SJ01-2AB0', '6AG1512-1DK01-7AB0', '6AG2512-1DK01-4AB0', '6AG1510-1DJ01-7AB0', '6AG2512-1SK01-4AB0', '6AG2510-1DJ01-1AB0', '6AG2512-1SK01-1AB0', '6AG2510-1DJ01-4AB0', '6AG2510-1SJ01-1AB0', '6AG1510-1DJ01-2AB0', '6AG1512-1SK01-2AB0', '6AG2512-1DK01-1AB0', '6AG1512-1DK01-2AB0', '6AG1512-1SK01-7AB0']},
"cpe:/o:siemens:siplus_s7-1200_cpu_firmware" :
{"versionEndExcluding" : "4.7.0", "family" : "S71200", "orderNumbers" : ['6AG1214-1HG40-5XB0', '6AG1214-1BG40-5XB0', '6AG1214-1BG40-2XB0', '6AG1212-1BE40-4XB0', '6AG1215-1HG40-4XB0', '6AG2214-1AG40-1XB0', '6AG1212-1BE40-2XB0', '6AG1214-1AF40-5XB0', '6AG1215-1BG40-2XB0', '6AG1215-1AG40-2XB0', '6AG1212-1AE40-2XB0', '6AG1214-1AG40-4XB0', '6AG1214-1AG40-2XB0', '6AG1215-1BG40-4XB0', '6AG1215-1BG40-5XB0', '6AG1215-1AG40-4XB0', '6AG1215-1HG40-2XB0', '6AG1212-1AE40-4XB0', '6AG2212-1AE40-1XB0', '6AG1214-1AG40-5XB0', '6AG1215-1HG40-5XB0', '6AG1214-1HG40-2XB0', '6AG1214-1HF40-5XB0', '6AG1215-1AG40-5XB0', '6AG1214-1BG40-4XB0', '6AG1215-1AF40-5XB0', '6AG1212-1HE40-4XB0', '6AG1212-1HE40-2XB0', '6AG1214-1HG40-4XB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware" :
{"family" : "S71500", "orderNumbers" : ['6AG1515-2FM01-2AB0', '6AG2516-3AN01-4AB0', '6AG1511-1AK02-2AB0', '6AG2516-3FN02-4AB0', '6AG1516-3AN01-2AB0', '6AG1513-1AL02-7AB0', '6AG1516-3AN01-7AB0', '6AG1511-1AK01-2AB0', '6AG1513-1FL01-2AB0', '6AG1516-3FN02-2AB0', '6AG1516-3AN02-2AB0', '6AG2511-1AK01-4AB0', '6AG2511-1AK01-1AB0', '6AG2511-1AK02-1AB0', '6AG1511-1AK02-7AB0', '6AG1511-1FK01-2AB0', '6AG1511-1AK01-7AB0', '6AG1516-3FN01-2AB0', '6AG2511-1AK02-4AB0', '6AG2516-3FN02-2AB0', '6AG1511-1FK02-2AB0', '6AG2515-2FM01-2AB0', '6AG1513-1FL02-2AB0', '6AG2515-2FM02-4AB0', '6AG2516-3AN02-4AB0', '6AG1513-1AL02-2AB0', '6AG1515-2FM02-2AB0', '6AG1513-1AL01-7AB0', '6AG1513-1AL01-2AB0', '6AG2515-2RM00-4AB0', '6AG1516-3AN02-7AB0']},
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.4" :
{"versionEndExcluding" : "3.1.4", "family" : "S71500", "orderNumbers" : ['6ES7514-2WN03-0AB0', '6ES7515-2AN03-0AB0', '6ES7518-4AP00-0AB0', '6ES7512-1DM03-0AB0', '6ES7518-4AX00-1AC0', '6ES7517-3FP01-0AB0', '6ES7510-1SK03-0AB0', '6ES7513-2GM03-0AB0', '6ES7516-3UN00-0AB0', '6ES7516-3FP03-0AB0', '6ES7518-4UP00-0AB0', '6ES7516-2PP03-0AB0', '6ES7516-3AP03-0AB0', '6ES7518-4FP00-0AB0', '6ES7513-2PM03-0AB0', '6ES7518-4FX00-1AB0', '6ES7516-3TN00-0AB0', '6ES7514-2DN03-0AB0', '6ES7513-1AM03-0AB0', '6ES7511-1AL03-0AB0', '6ES7513-1FM03-0AB0', '6ES7516-2GP03-0AB0', '6ES7512-1SM03-0AB0', '6ES7510-1DK03-0AB0', '6ES7517-3TP00-0AB0', '6ES7512-1CM03-0AB0', '6ES7518-4AX00-1AB0', '6ES7511-1CL03-0AB0', '6ES7515-2FN03-0AB0', '6ES7518-4TP00-0AB0', '6ES7511-1FL03-0AB0', '6ES7517-3FP00-0AB0', '6ES7511-1UL03-0AB0', '6ES7518-4FX00-1AC0', '6ES7514-2VN03-0AB0', '6ES7514-2SN03-0AB0', '6ES7515-2UN03-0AB0', '6ES7511-1TL03-0AB0', '6ES7517-3AP00-0AB0', '6ES7517-3UP00-0AB0', '6ES7515-2TN03-0AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.4" :
{"versionEndExcluding" : "3.1.4", "family" : "S71500", "orderNumbers" : ['6AG1518-4AP00-4AB0', '6AG1518-4AX00-4AC0', '6AG1518-4FP00-4AB0']},
"cpe:/o:siemens:simatic_drive_controller_cpu_firmware:3.1.4" :
{"versionEndExcluding" : "3.1.4", "family" : "S71500", "orderNumbers" : ['6ES7615-4DF10-0AB0', '6ES7615-7DF10-0AB0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
30 Jul 2026 00:00Current
5.9Medium risk
Vulners AI Score5.9
CVSS 3.14.7
CVSS 45.1
EPSS0.00378
SSVC