Siemens SIMATIC S7-1500 TM MFP NULL Pointer Dereference (CVE-2024-41055)

🗓️ 17 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 21 Views

Siemens SIMATIC S7-1500 TM MFP has a fixed NULL pointer dereference vulnerability (CVE-2024-41055).

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503140);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/17");

  script_cve_id("CVE-2024-41055");
  script_xref(name:"ICSA", value:"25-072-03");

  script_name(english:"Siemens SIMATIC S7-1500 TM MFP NULL Pointer Dereference (CVE-2024-41055)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
mm: prevent derefencing NULL ptr in pfn_section_valid() Commit
5ec8e8ea8b77 (mm/sparsemem: fix race in accessing
memory_section->usage) changed pfn_section_valid() to add a
READ_ONCE() call around ms->usage to fix a race with
section_deactivate() where ms->usage can be cleared. The READ_ONCE()
call, by itself, is not enough to prevent NULL pointer dereference. We
need to check its value before dereferencing it.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-503939.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-03");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-41055");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(476);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/03/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/03/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/17");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
        {"family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

17 Mar 2025 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 3.15.5
EPSS0.00255
SSVC
21