| Reporter | Title | Published | Views | Family All 132 |
|---|---|---|---|---|
| Astra Linux – Vulnerability in Linux 6.1 | 11 Feb 202507:35 | – | astralinux | |
| The vulnerability of DRM/LIMA components in Linux operating systems allows attackers to increase their privileges within the system. | 3 Feb 202500:00 | – | bdu_fstec | |
| CVE-2024-40976 | 14 Aug 202510:00 | – | circl | |
| Linux kernel security vulnerabilities | 12 Jul 202400:00 | – | cnnvd | |
| CVE-2024-40976 | 12 Jul 202412:32 | – | cve | |
| CVE-2024-40976 drm/lima: mask irqs in timeout path before hard reset | 12 Jul 202412:32 | – | cvelist | |
| [SECURITY] [DLA 4008-1] linux-6.1 security update | 3 Jan 202500:41 | – | debian | |
| [SECURITY] [DSA 5730-1] linux security update | 15 Jul 202420:09 | – | debian | |
| [SECURITY] [DSA 5731-1] linux security update | 16 Jul 202420:58 | – | debian | |
| CVE-2024-40976 | 12 Jul 202412:32 | – | debiancve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504455);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");
script_cve_id("CVE-2024-40976");
script_xref(name:"ICSA", value:"25-226-07");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40976)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"drm/lima: There is a race condition in which a rendering job might
take just long enough to trigger the drm sched job timeout handler but
also still complete before the hard reset is done by the timeout
handler. This runs into race conditions not expected by the timeout
handler. In some very specific cases it currently may result in a
refcount imbalance on lima_pm_idle, with a stack dump.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-40976");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xcm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xch-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrh-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation