| Reporter | Title | Published | Views | Family All 15 |
|---|---|---|---|---|
| The vulnerability of the web servers of the microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP allows a perpetrator to cause service interruptions. | 18 Sep 202400:00 | – | bdu_fstec | |
| CVE-2022-43716 | 11 Apr 202314:23 | – | circl | |
| Siemens SIMATIC CP443-1 OPC UA9 资源管理错误漏洞 | 11 Apr 202300:00 | – | cnnvd | |
| Denial of Service Vulnerability in Multiple Siemens Products (CNVD-2023-35756) | 16 Apr 202300:00 | – | cnvd | |
| CVE-2022-43716 | 11 Apr 202309:02 | – | cve | |
| CVE-2022-43716 | 11 Apr 202309:02 | – | cvelist | |
| EUVD-2022-46698 | 3 Oct 202520:07 | – | euvd | |
| Siemens Industrial Products | 11 Apr 202300:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 11 Apr 202300:00 | – | ncsc | |
| CVE-2022-43716 | 11 Apr 202310:15 | – | nvd |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501107);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/10");
script_cve_id("CVE-2022-43716");
script_xref(name:"ICSA", value:"23-103-10");
script_name(english:"Siemens Industrial Products Use After Free (CVE-2022-43716)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All
versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3
(incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl.
SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All
versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8
IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP
1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions),
SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions
< V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC IPC
DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions),
SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET
200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1
ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions),
SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1
Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All
versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM
1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions <
V2.3.6). The webserver of the affected products contains a
vulnerability that may lead to a denial of service condition. An
attacker may cause a denial of service situation which leads to a
restart of the webserver of the affected product.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-10");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has released updates for several affected products and recommends updating to the latest versions. Siemens is
preparing further updates and recommends specific countermeasures for products where updates are not, or not yet,
available:
- SIMATIC CP 443-1 (6GK7443-1EX30-0XE0): Update to V3.3 or later version
- SIMATIC CP 443-1 (6GK7443-1EX30-0XE1): Update to V3.3 or later version
- SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0): Update to V3.3 or later version
- SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0): Update to V2.3.6 or later version
- TIM 1531 IRC (6GK7543-1MX00-0XE0): Update to V2.3.6 or later version
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- Restrict access to the web interface of the affected productsâif deactivation unsupported by the product.
- Deactivate the webserver if not required and if deactivation is supported by the product.
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment
according to Siemens' Operational Guidelines for Industrial Security and to follow the recommendations in the product
manuals. Additional information on Industrial Security by Siemens can be found on the Siemens webpage for Industrial
Security.
For further inquiries on security vulnerabilities in Siemensâ products and solutions, users should contact the Siemens
ProductCERT.
For more information, see the associated Siemens security advisory SSA-566905 in HTML and CSAF.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-43716");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(416);
script_set_attribute(attribute:"vuln_publication_date", value:"2023/04/11");
script_set_attribute(attribute:"patch_publication_date", value:"2023/04/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/05/02");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1242-7_v2_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-1_dnp3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-1_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-1_iec_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-7_lte_eu_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-7_lte_us_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1243-8_irc_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1542sp-1_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_1543sp-1_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_443-1_advanced_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_cp_443-1_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:2.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_cp_1242-7_v2_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_cp_443-1_advanced_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_cp_443-1_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1200_cp_1243-1_firmware:3.4.29");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:3.4.29");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_cp_1542sp-1_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "S71500", "orderNumbers" : ['6GK7542-6UX00-0XE0']},
"cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "S71500", "orderNumbers" : ['6GK7542-6VX00-0XE0']},
"cpe:/o:siemens:simatic_cp_1543sp-1_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "S71500", "orderNumbers" : ['6GK7543-6WX00-0XE0']},
"cpe:/o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "ET200", "orderNumbers" : ['6AG2542-6VX00-4XE0']},
"cpe:/o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "ET200", "orderNumbers" : ['6AG1543-6WX00-7XE0']},
"cpe:/o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:2.3" :
{"versionEndExcluding" : "2.3", "family" : "ET200", "orderNumbers" : ['6AG2543-6WX00-4XE0']},
"cpe:/o:siemens:simatic_cp_443-1_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "S7400", "orderNumbers" : ['6GK7443-1EX30-0XE0', '6GK7443-1EX30-0XE1']},
"cpe:/o:siemens:simatic_cp_443-1_advanced_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "S7400", "orderNumbers" : ['6GK7443-1GX30-0XE0']},
"cpe:/o:siemens:siplus_net_cp_443-1_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "S7400", "orderNumbers" : ['6AG1443-1EX30-4XE0']},
"cpe:/o:siemens:siplus_net_cp_443-1_advanced_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "S7400", "orderNumbers" : ['6AG1443-1GX30-4XE0']},
"cpe:/o:siemens:simatic_cp_1242-7_v2_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6GK7242-7KX31-0XE0']},
"cpe:/o:siemens:simatic_cp_1243-1_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6GK7243-1BX30-0XE0']},
"cpe:/o:siemens:simatic_cp_1243-1_dnp3_firmware" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200"},
"cpe:/o:siemens:simatic_cp_1243-1_iec_firmware" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200"},
"cpe:/o:siemens:simatic_cp_1243-7_lte_eu_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6GK7243-7KX30-0XE0']},
"cpe:/o:siemens:simatic_cp_1243-7_lte_us_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6GK7243-7SX30-0XE0']},
"cpe:/o:siemens:simatic_cp_1243-8_irc_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6GK7243-8RX30-0XE0']},
"cpe:/o:siemens:siplus_net_cp_1242-7_v2_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6AG1242-7KX31-7XE0']},
"cpe:/o:siemens:siplus_s7-1200_cp_1243-1_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6AG1243-1BX30-2AX0']},
"cpe:/o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:3.4.29" :
{"versionEndExcluding" : "3.4.29", "family" : "S71200", "orderNumbers" : ['6AG2243-1BX30-1XE0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation