Lucene search
+L

Siemens InsydeH2O Inclusion of Functionality from Untrusted Control Sphere (CVE-2021-41841)

🗓️ 26 Sep 2023 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 22 Views

InsydeH2O BIOS vulnerability allows attacker access to System Management Mode

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501722);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/27");

  script_cve_id("CVE-2021-41841");

  script_name(english:"Siemens InsydeH2O Inclusion of Functionality from Untrusted Control Sphere (CVE-2021-41841)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in
Insyde InsydeH2O. There is an SMM callout that allows an attacker to
access the System Management Mode and execute arbitrary code. This
occurs because of Inclusion of Functionality from an Untrusted Control
Sphere.

Insyde BIOS is typically used in RUGGEDCOM APE products 
and some SIMATIC devices. Please refer to the vendor advisory for a 
precise list of models concerned.

This plugin only works with Tenable.ot
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge/SA-2022019");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220217-0012/");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-41841");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(829);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/26");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/a:insyde:insydeh2o:5.0" :
        {"versionEndExcluding" : "5.08.29", "versionStartIncluding" : "5.0", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.1" :
        {"versionEndExcluding" : "5.16.29", "versionStartIncluding" : "5.1", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.2" :
        {"versionEndExcluding" : "5.26.29", "versionStartIncluding" : "5.2", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.3" :
        {"versionEndExcluding" : "5.35.29", "versionStartIncluding" : "5.3", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.4" :
        {"versionEndExcluding" : "5.43.29", "versionStartIncluding" : "5.4", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.5" :
        {"versionEndExcluding" : "5.51.29", "versionStartIncluding" : "5.5", "family" : "APE1808"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation