Siemens SIMATIC S7-1500 Uncontrolled Resource Consumption (CVE-2021-3737)

🗓️ 13 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

CVE-2021-3737: Siemens S7-1500 flaw; Python HTTP client loop causes CPU exhaustion.

Related
Refs
Code
ReporterTitlePublishedViews
Family
IBM Security Bulletins
Security Bulletin: IBM Cloud Transformation Advisor is vulnerable to multiple vulnerabilities found in Java, Node.js and IBM WebSphere Application Server Liberty
15 Apr 202502:54
ibm
IBM Security Bulletins
Security Bulletin: IBM Security Guardium Insights is affected by multipe vulnerabilities
4 Feb 202221:33
ibm
IBM Security Bulletins
Security Bulletin: IBM Watson Speech Services Cartridge for IBM Cloud Pak for Data is vulnerable to a denial of service in Python (CVE-2021-3737)
12 Jan 202321:59
ibm
IBM Security Bulletins
Security Bulletin: IBM Cognos Analytics has addressed multiple vulnerabilities (CVE-2022-34339, CVE-2021-3712, CVE-2021-3711, CVE-2021-4160, CVE-2021-29425, CVE-2021-3733, CVE-2021-3737, CVE-2022-0391, CVE-2021-43138, CVE-2022-24758)
26 Mar 202502:27
ibm
IBM Security Bulletins
Security Bulletin: IBM QRadar SIEM includes components with known vulnerabilities
6 Jul 202318:48
ibm
IBM Security Bulletins
Security Bulletin: IBM Cloud Pak for Security includes components with multiple known vulnerabilities
16 Jun 202315:20
ibm
IBM Security Bulletins
Security Bulletin: A buffer overread, security restrictions bypass, a use-after-free, and other vulnerabilities might affect IBM Storage Defender – Resiliency Service
25 Mar 202523:50
ibm
IBM Security Bulletins
Security Bulletin: IBM Watson Discovery for IBM Cloud Pak for Data affected by vulnerability in Python
29 Jun 202202:19
ibm
IBM Security Bulletins
Security Bulletin: CVE-2021-44228 log4j affects MAS Monitor 8.4, 8.5 and 8.6
28 Mar 202217:15
ibm
IBM Security Bulletins
Security Bulletin: Netcool Operations Insight v1.6.7 contains fixes for multiple security vulnerabilities.
15 Dec 202209:13
ibm
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504155);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2021-3737");
  script_xref(name:"ICSA", value:"23-348-10");

  script_name(english:"Siemens SIMATIC S7-1500 Uncontrolled Resource Consumption (CVE-2021-3737)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A flaw was found in python. An improperly handled HTTP response in the
HTTP client code of python may allow a remote attacker, who controls
the HTTP server, to make the client script enter an infinite loop,
consuming CPU time. The highest threat from this vulnerability is to
system availability.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0): Only build and run applications from trusted sources.
Currently no fix is available.

Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions prior to V3.1 refer to
SiemensSecurity Bulletin SSB-439005.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-398330 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-3737");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(400);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
6.9Medium risk
Vulners AI Score6.9
CVSS 27.1
CVSS 3.17.5
EPSS0.11994
SSVC
2