Siemens SCALANCE Improper Validation of Integrity Check Value(CVE-2020-26141)
| Reporter | Title | Published | Views | Family All 255 |
|---|---|---|---|---|
| Amazon Linux 2 : kernel, --advisory ALAS2KERNEL-5.10-2022-002 (ALASKERNEL-5.10-2022-002) | 2 May 202200:00 | – | nessus | |
| Amazon Linux 2 : kernel, --advisory ALAS2KERNEL-5.4-2022-004 (ALASKERNEL-5.4-2022-004) | 2 May 202200:00 | – | nessus | |
| AlmaLinux 8 : kernel (ALSA-2021:4356) | 9 Feb 202200:00 | – | nessus | |
| CentOS 8 : kernel-rt (CESA-2021:4140) | 11 Nov 202100:00 | – | nessus | |
| CentOS 8 : kernel (CESA-2021:4356) | 11 Nov 202100:00 | – | nessus | |
| EulerOS 2.0 SP5 : kernel (EulerOS-SA-2021-2663) | 11 Nov 202100:00 | – | nessus | |
| EulerOS 2.0 SP8 : kernel (EulerOS-SA-2022-1366) | 11 Apr 202200:00 | – | nessus | |
| EulerOS Virtualization 3.0.2.0 : kernel (EulerOS-SA-2022-1681) | 7 May 202200:00 | – | nessus | |
| EulerOS 2.0 SP3 : kernel (EulerOS-SA-2022-1735) | 26 May 202200:00 | – | nessus | |
| EulerOS Virtualization 3.0.6.0 : kernel (EulerOS-SA-2022-2566) | 10 Oct 202200:00 | – | nessus |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505331);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/23");
script_cve_id("CVE-2020-26141");
script_xref(name:"ICSA", value:"22-104-04");
script_name(english:"Siemens SCALANCE Improper Validation of Integrity Check Value(CVE-2020-26141)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for
AWUS036H. The Wi-Fi implementation does not verify the Message
Integrity Check (authenticity) of fragmented TKIP frames. An adversary
can abuse this to inject and possibly decrypt packets in WPA or WPA2
networks that support the TKIP data-confidentiality protocol.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-913875.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-019200.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109996102/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-04");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:A/AC:L/Au:N/C:N/I:P/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-26141");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(354);
script_set_attribute(attribute:"vuln_publication_date", value:"2021/07/13");
script_set_attribute(attribute:"patch_publication_date", value:"2021/07/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/04/21");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w721-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w722-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w734-1_rj45_%28usa%29_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w734-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w738-1_m12_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w748-1_m12_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w748-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w761-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w774-1_m12_eec_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w774-1_rj45_%28usa%29_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w774-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w778-1_m12_eec_%28usa%29_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w778-1_m12_eec_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w778-1_m12_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w786-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w786-2_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w786-2_sfp_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w786-2ia_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w788-1_m12_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w788-1_rj45_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w788-2_m12_eec_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w788-2_m12_firmware:6.6.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w788-2_rj45_firmware:6.6.0");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:scalance_w721-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5721-1FC00-0AA0', '6GK5721-1FC00-0AB0']},
"cpe:/o:siemens:scalance_w722-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5722-1FC00-0AB0', '6GK5722-1FC00-0AC0', '6GK5722-1FC00-0AA0']},
"cpe:/o:siemens:scalance_w734-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5734-1FX00-0AA0', '6GK5734-1FX00-0AB0', '6GK5734-1FX00-0AA6']},
"cpe:/o:siemens:scalance_w734-1_rj45_%28usa%29_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5734-1FX00-0AB6']},
"cpe:/o:siemens:scalance_w738-1_m12_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5738-1GY00-0AA0', '6GK5738-1GY00-0AB0']},
"cpe:/o:siemens:scalance_w748-1_m12_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5748-1GD00-0AB0', '6GK5748-1GD00-0AA0']},
"cpe:/o:siemens:scalance_w748-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5748-1FC00-0AA0', '6GK5748-1FC00-0AB0']},
"cpe:/o:siemens:scalance_w761-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5761-1FC00-0AA0', '6GK5761-1FC00-0AB0']},
"cpe:/o:siemens:scalance_w774-1_m12_eec_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5774-1FY00-0TB0', '6GK5774-1FY00-0TA0']},
"cpe:/o:siemens:scalance_w774-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5774-1FX00-0AA6', '6GK5774-1FX00-0AA0', '6GK5774-1FX00-0AC0', '6GK5774-1FX00-0AB0']},
"cpe:/o:siemens:scalance_w774-1_rj45_%28usa%29_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5774-1FX00-0AB6']},
"cpe:/o:siemens:scalance_w778-1_m12_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5778-1GY00-0AA0', '6GK5778-1GY00-0AB0']},
"cpe:/o:siemens:scalance_w778-1_m12_eec_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5778-1GY00-0TA0']},
"cpe:/o:siemens:scalance_w778-1_m12_eec_%28usa%29_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5778-1GY00-0TB0']},
"cpe:/o:siemens:scalance_w786-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5786-1FC00-0AA0', '6GK5786-1FC00-0AB0']},
"cpe:/o:siemens:scalance_w786-2_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5786-2FC00-0AC0', '6GK5786-2FC00-0AA0', '6GK5786-2FC00-0AB0']},
"cpe:/o:siemens:scalance_w786-2_sfp_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5786-2FE00-0AA0', '6GK5786-2FE00-0AB0']},
"cpe:/o:siemens:scalance_w786-2ia_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5786-2HC00-0AB0', '6GK5786-2HC00-0AA0']},
"cpe:/o:siemens:scalance_w788-1_m12_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5788-1GD00-0AA0', '6GK5788-1GD00-0AB0']},
"cpe:/o:siemens:scalance_w788-1_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5788-1FC00-0AB0', '6GK5788-1FC00-0AA0']},
"cpe:/o:siemens:scalance_w788-2_m12_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5788-2GD00-0AA0', '6GK5788-2GD00-0AB0']},
"cpe:/o:siemens:scalance_w788-2_m12_eec_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5788-2GD00-0TB0', '6GK5788-2GD00-0TC0', '6GK5788-2GD00-0TA0']},
"cpe:/o:siemens:scalance_w788-2_rj45_firmware:6.6.0" :
{"versionEndExcluding" : "6.6.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5788-2FC00-0AB0', '6GK5788-2FC00-0AC0', '6GK5788-2FC00-0AA0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_NOTE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
23 Apr 2026 00:00Current
6.9Medium risk
Vulners AI Score6.9
CVSS 23.3
CVSS 3.16.5
EPSS0.03072