Lucene search
K

Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2016-10012)

🗓️ 13 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 8 Views

Siemens SCALANCE X-200RNA Switch devices have a memory buffer vulnerability affecting operations.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503106);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/13");

  script_cve_id("CVE-2016-10012");
  script_xref(name:"ICSA", value:"22-349-21");

  script_name(english:"Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2016-10012)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The shared memory manager (associated with pre-authentication
compression) in sshd in OpenSSH before 7.4 does not ensure that a
bounds check is enforced by all compilers, which might allows local
users to gain privileges by leveraging access to a sandboxed
privilege-separation process, related to the m_zback and m_zlib data
structures.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814809/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-10012");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
    "cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

13 Mar 2025 00:00Current
7High risk
Vulners AI Score7
CVSS 27.2
CVSS 37.8
CVSS 3.17.8
EPSS0.01281
SSVC
8