This advisory is a follow-up to the alert titled ICS-ALERT-16-256-02 Schneider Electric ION Power Meter CSRF Vulnerability that was published September 12, 2016, on the NCCIC/ICS-CERT web site.
Independent researcher Karn Ganeshen has identified a cross-site request forgery (CSRF) and no access control vulnerabilities in Schneider Electric’s IONXXXX series power meters. Schneider Electric has produced instructions to mitigate these vulnerabilities.
These vulnerabilities could be exploited remotely.
The following IONXXXX series power meter versions are affected:
An unauthorized user can access the device management portal and make configuration changes.
Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation.
Schneider Electric’s corporate headquarters is located in Paris, France, and maintains offices in more than 100 countries worldwide.
The affected products, IONXXXX series power meters, provide power and energy monitoring. According to Schneider Electric, these products are deployed across several sectors including Critical Manufacturing, Energy, Water and Wastewater Systems, and others. Schneider Electric estimates that these products are used worldwide.
There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
CVE-2016-5809NVD, https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-5809, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:HA:H).CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, web site last accessed November 3, 2016.
No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
CVE-2016-5815NVD, https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-5815, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:HA:N).CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N, web site last accessed November 3, 2016.
These vulnerabilities could be exploited remotely.
No known public exploits specifically target these vulnerabilities.
An attacker with a low skill would be able to exploit these vulnerabilities.
Schneider Electric’s security notice SEVD-2016-256-02, is available at the following location:
<http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page>,
Schneider Electric recommends the following mitigations:
ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
twitter.com/CISAgov
twitter.com/intent/tweet?text=Schneider%20Electric%20IONXXXX%20Series%20Power%20Meter%20Vulnerabilities+https://www.cisa.gov/news-events/ics-advisories/icsa-16-308-03
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-16-308-03&title=Schneider%20Electric%20IONXXXX%20Series%20Power%20Meter%20Vulnerabilities
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-16-308-03
www.oig.dhs.gov/
www.surveymonkey.com/r/CISA-cyber-survey?product=https://www.cisa.gov/news-events/ics-advisories/icsa-16-308-03
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Schneider%20Electric%20IONXXXX%20Series%20Power%20Meter%20Vulnerabilities&body=www.cisa.gov/news-events/ics-advisories/icsa-16-308-03
7.5 High
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
9.8 High
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
0.002 Low
EPSS
Percentile
60.0%