**ATTENTION:**Remotely exploitable/low skill level to exploit.
Vendor: Siemens
Equipment: SIMATIC Logon
Vulnerability: Out-of-Bounds Write
Siemens reports that the vulnerability affects the following SIMATIC Logon products:
Successful exploitation of this vulnerability could allow attackers to cause a denial of service of the SIMATIC Logon Remote Access service under certain conditions.
Siemens created a software upgrade V1.6 for SIMATIC Logon which fixes the vulnerability, and they recommend users upgrade to the newest version. Please contact the local Siemens representative or customer support at the following location:
<https://www.siemens.de/automation/partner>
Siemens strongly recommends users protect network access to the Port 16389/TCP of the SIMATIC Logon Remote Access service with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemensβ Operational Guidelines for Industrial Security:
<https://www.siemens.com/cert/operational-guidelines-industrial-security>
For a more specific list of affected products and more detailed mitigation instructions, please see Siemens Security Advisory SSA-804859 at the following location:
<http://www.siemens.com/cert/advisories>
NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICSβCERT Technical Information Paper, ICS-TIP-12-146-01BβTargeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.
Specially crafted packets sent to the SIMATIC Logon Remote Access service on Port 16389/TCP could cause a denial-of-service condition. The service restarts automatically.
CVE-2017-9938 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
Tenable Network Security reported this vulnerability to Siemens.
Critical Infrastructure Sectors: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9938
www.siemens.com/cert/advisories
cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/news-events/ics-advisories/icsa-17-192-01
cwe.mitre.org/data/definitions/787.html
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
twitter.com/CISAgov
twitter.com/intent/tweet?text=Siemens%20SIMATIC%20Logon+https://www.cisa.gov/news-events/ics-advisories/icsa-17-192-01
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-17-192-01&title=Siemens%20SIMATIC%20Logon
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-17-192-01
www.oig.dhs.gov/
www.siemens.com/cert/operational-guidelines-industrial-security
www.siemens.de/automation/partner
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Siemens%20SIMATIC%20Logon&body=www.cisa.gov/news-events/ics-advisories/icsa-17-192-01
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:N/I:N/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
Percentile
70.6%