Lucene search

K
cvelistIcscertCVELIST:CVE-2024-29082
HistoryAug 08, 2024 - 7:23 p.m.

CVE-2024-29082 Vonets WiFi Bridges Improper Access Control

2024-08-0819:23:23
CWE-284
icscert
www.cve.org
5
vonets
wifi bridges
improper access control
industrial
vulnerability
remote attacker
authentication
factory reset
unprotected endpoints

CVSS3

8.6

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H

CVSS4

8.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/SC:N/VI:L/SI:N/VA:H/SA:N

EPSS

0.001

Percentile

17.7%

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9
and prior, enables an unauthenticated remote attacker to bypass
authentication and factory reset the device via unprotected goform
endpoints.

CNA Affected

[
  {
    "defaultStatus": "unaffected",
    "product": "VAR1200-H",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAR1200-L",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAR600-H",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11AC",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11G-500S",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VBG1200",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11S-5G",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11S",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAR11N-300",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11G-300",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11N-300",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11G",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11G-500",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VBG1200",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VAP11AC",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VGA-1000",
    "vendor": "Vonets",
    "versions": [
      {
        "lessThanOrEqual": "3.3.23.6.9",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  }
]

CVSS3

8.6

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H

CVSS4

8.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/SC:N/VI:L/SI:N/VA:H/SA:N

EPSS

0.001

Percentile

17.7%

Related for CVELIST:CVE-2024-29082