Lucene search

K
cve[email protected]CVE-2022-30316
HistoryJul 28, 2022 - 4:15 p.m.

CVE-2022-30316

2022-07-2816:15:00
CWE-354
web.nvd.nist.gov
28
4
cve-2022-30316
honeywell experion pks
safety manager
firmware update
data authenticity
remote code execution
denial of service
authentication
vulnerability

6.8 Medium

CVSS3

Attack Vector

PHYSICAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

7.9 High

AI Score

Confidence

High

4.6 Medium

CVSS2

Access Vector

LOCAL

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:L/AC:L/Au:N/C:P/I:P/A:P

0.002 Low

EPSS

Percentile

54.2%

Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.

Social References

More

6.8 Medium

CVSS3

Attack Vector

PHYSICAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

7.9 High

AI Score

Confidence

High

4.6 Medium

CVSS2

Access Vector

LOCAL

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:L/AC:L/Au:N/C:P/I:P/A:P

0.002 Low

EPSS

Percentile

54.2%

Related for CVE-2022-30316