Lucene search

K
zdtChizuru Toyama1337DAY-ID-39143
HistoryNov 14, 2023 - 12:00 a.m.

LOYTEC Electronics Insecure Transit / Insecure Permissions / Unauthenticated Access Vulnerabilities

2023-11-1400:00:00
Chizuru Toyama
0day.today
205
insecure permissions
unauthenticated access
http transmission
authentication missing
data theft
account takeover
web interface
network sniffing
system logs
public disclosure
trend micro zdi
ics cert

8.2 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

HIGH

Availability Impact

LOW

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L

7.5 High

AI Score

Confidence

Low

0.001 Low

EPSS

Percentile

31.4%

Products from LOYTEC electronics such as Loytec LWEB-802, L-INX Automation Servers, L-IOB I/O Controllers, and L-VIS Touch Panels suffer from improper access control and insecure transit vulnerabilities.

[+] CVE                                 : CVE-2023-46380, CVE-2023-46381, CVE-2023-46382 
[+] Title                                : Multiple vulnerabilities in Loytec LWEB-802, L-INX Automation Servers, L-IOB I/O Controllers, L-VIS Touch Panels 
[+] Vendor                           : LOYTEC electronics GmbH
[+] Affected Product(s)     : LINX-212 firmware 6.2.4, LVIS-3ME12-A1 firmware 6.2.2, LIOB-586 firmware 6.2.3
[+] Affected Components : LWEB-802, L-INX Automation Servers, L-IOB I/O Controllers, L-VIS Touch Panels 
[+] Discovery Date             : 01-Sep-2021
[+] Publication date           : 03-Nov-2023
[+] Discovered by               : Chizuru Toyama of TXOne networks


[Vulnerability Description]

 CVE-2023-46380 : Insecure Permissions
 Password change request on the web interface on LOYTEC devices is sent
 in clear text over HTTP, and this allows information theft and account 
 takeover via network sniffing.

 CVE-2023-46381 : Improper Access Control
 Authentication is missing on the web user interface for the preinstalled 
 version of LWEB-802. If there is a project on a device, an unauthenticated 
 user could create a new project on a web and access/control a graphical 
 interface. An unauthenticated user also could edit or delete a current 
 web project, change settings and delete system logs etc...
 http://<IP>:<port>/lweb802_pre/

 CVE-2023-46382 : Insecure Permissions
 The web user interface on Loytec devices requires login credentials for 
 critical information (Data, Commission, Config, etc...); however, username 
 and password information is sent in clear text over HTTP. If anyone sniff 
 network traffic, they could easily steal credentials.


[Timeline]

 01-Sep-2021 : Vulnerabilities discovered
 13-Oct-2021 : Trend Micro ZDI (Zero Day Initiative) reported to vendor (no response)
 07-Oct-2022 : ICS CERT reported to vendor (no response)
 03-Nov-2023 : Public disclosure

8.2 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

HIGH

Availability Impact

LOW

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L

7.5 High

AI Score

Confidence

Low

0.001 Low

EPSS

Percentile

31.4%

Related for 1337DAY-ID-39143