added 2025/06/09 6:15 a.m.47 views

CVE-2025-5863

A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9.8CVSS8.9AI score0.00138EPSS
CVE
CVE
added 2025/06/06 7:15 p.m.42 views

CVE-2025-5795

A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has be...

9CVSS8.9AI score0.00096EPSS
CVE
CVE
added 2023/07/14 12:15 a.m.41 views

CVE-2023-37717

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.41 views

CVE-2023-41553

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/07/14 12:15 a.m.40 views

CVE-2023-37716

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38930

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38936

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.

9.8CVSS9.6AI score0.00334EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38937

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2025/06/06 7:15 p.m.39 views

CVE-2025-5794

A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploi...

9CVSS8.8AI score0.00096EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.37 views

CVE-2023-41562

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.36 views

CVE-2023-38933

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.36 views

CVE-2023-41563

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.35 views

CVE-2023-41561

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.34 views

CVE-2023-38931

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.34 views

CVE-2023-41556

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.31 views

CVE-2023-41559

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.29 views

CVE-2023-38935

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.

9.8CVSS9.6AI score0.00098EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.28 views

CVE-2023-41557

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2025/06/30 5:15 a.m.8 views

CVE-2025-6886

A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be laun...

9CVSS8.9AI score0.00084EPSS
CVE
CVE
added 2025/06/30 5:15 a.m.6 views

CVE-2025-6887

A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploi...

9CVSS8.8AI score0.00084EPSS