Lucene search

K

22 matches found

CVE
CVE
added 2012/02/03 8:55 p.m.63 views

CVE-2011-4509

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS6.7AI score0.00634EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.55 views

CVE-2011-4508

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

9.3CVSS6.8AI score0.00192EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.54 views

CVE-2011-4875

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled,...

9.3CVSS8.2AI score0.36694EPSS
CVE
CVE
added 2012/09/18 2:55 p.m.50 views

CVE-2012-3032

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

7.5CVSS8.4AI score0.00538EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.49 views

CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is en...

9.3CVSS6.9AI score0.16825EPSS
CVE
CVE
added 2012/09/18 2:55 p.m.47 views

CVE-2012-3028

Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.

6.8CVSS7.5AI score0.0017EPSS
CVE
CVE
added 2012/09/18 2:55 p.m.47 views

CVE-2012-3031

Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.

4.3CVSS5.8AI score0.00589EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.46 views

CVE-2011-4511

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtim...

4.3CVSS5.7AI score0.00385EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.45 views

CVE-2011-4514

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS6.6AI score0.00549EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.45 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS6.7AI score0.2369EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.45 views

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

7.8CVSS6.8AI score0.28229EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.44 views

CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

8.5CVSS6.9AI score0.39573EPSS
CVE
CVE
added 2012/06/08 6:55 p.m.44 views

CVE-2012-3003

Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.

5.8CVSS6.9AI score0.00328EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.43 views

CVE-2011-4510

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtim...

4.3CVSS5.7AI score0.00385EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.43 views

CVE-2011-4512

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows rem...

5CVSS6.9AI score0.00385EPSS
CVE
CVE
added 2012/02/03 8:55 p.m.43 views

CVE-2011-4513

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, rela...

10CVSS7.8AI score0.03428EPSS
CVE
CVE
added 2012/06/08 6:55 p.m.43 views

CVE-2012-2596

The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack.

5.5CVSS6.2AI score0.00241EPSS
CVE
CVE
added 2012/06/08 6:55 p.m.43 views

CVE-2012-2598

Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.

4.3CVSS7AI score0.00496EPSS
CVE
CVE
added 2012/09/18 2:55 p.m.41 views

CVE-2012-3034

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.

4.3CVSS7AI score0.00518EPSS
CVE
CVE
added 2012/06/08 6:55 p.m.40 views

CVE-2012-2595

Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.

4.3CVSS5.7AI score0.00385EPSS
CVE
CVE
added 2012/06/08 6:55 p.m.39 views

CVE-2012-2597

Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.

4CVSS6.5AI score0.00181EPSS
CVE
CVE
added 2012/09/18 2:55 p.m.39 views

CVE-2012-3030

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

5CVSS6.4AI score0.00518EPSS