Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain a command injection vulnerability via the ipAddress parameter at 07system08execute_ping_01.
9.8CVSS
9.8AI Score
0.001EPSS
Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain an arbitrary file upload vulnerability via the restore backup function. This vulnerability allows attackers to execute arbitrary code via a crafted html file.
9.8CVSS
9.7AI Score
0.003EPSS
Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg.
9.8CVSS
9.4AI Score
0.003EPSS
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.
9.8CVSS
9.8AI Score
0.001EPSS
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
9.8CVSS
9.6AI Score
0.003EPSS
Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product.
6.5CVSS
6.3AI Score
0.003EPSS
Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions...
8.6CVSS
8.5AI Score
0.007EPSS
Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
7.5CVSS
7.5AI Score
0.002EPSS
Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the pro...
6.5CVSS
6.5AI Score
0.002EPSS
Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
7.5CVSS
7.8AI Score
0.007EPSS
Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product.
6.5CVSS
6AI Score
0.003EPSS
Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator's communication to the product.
6.5CVSS
6.4AI Score
0.005EPSS
Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product.
7.5CVSS
7.7AI Score
0.004EPSS
Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC ...